Total test time: 60 Minutes
1.2.2 Drop Test (Package, Non-Operating)
A) Drop Height
Drop test with packing gross weight and falling height relationship
Gross Weight
( Kg )
0.0<W<4.5
4.5 ≦ W<11.0
11.0 ≦ W<20.5
20.5 ≦ W<34.0
34.0 ≦ W<45.5
45.5 ≦ W<79.4
Test Orientation: 1 conner, 3 edges, 6 Faces.
After drop test,no abnormality on function /apperance.
Weight ( Kg )
B) Drop Sequence
select at weakness side [the low left(or right) corner of the front panel]
-An edge drop with impact on the shortest edge radiating from corner 5-3-2
-An edge drop with impact on the next shortest edge radiating from corner 5-3-2
-An edge drop with impact on the longest edge radiating from corner 5-3-2
-A flat drop with impact on the rear
-A flat drop with impact on the front
-A flat drop with impact on the right
-A flat drop with impact on the left
-A flat drop with impact on the bottom
Falling Height (cm) spec.
C3/C4/C5
106
106
91
76
61
46
BenQ Spec.Height (cm)
0 - 9
> 9 - 18
> 18 - 27
> 27 - 45
> 45 - 68
> 68
11
MP
Remark
106
91
76
61
46
31
91
76
61
46
31
26