Meter repairs
January 2024
3.5.2
T-200 transducer capsule assembly installation
This procedure is for installing a transducer capsule assembly into a transducer assembly
while it is installed in a meter body.
Procedure
1. Ensure that the transducer stalk, retainer and capsule assembly are clean and free
2. Record the serial number of the transducer capsule assembly to be installed and
58
of debris.
ensure it is correct for the intended transducer assembly.
Table 3-3: T-200 transducer stalk assembly configuration and capsule setting
Stalk assembly configuration
-01
-02
-03
-04
-05
-06
-07
-08
-09
-10
-11
-12
-13
Figure 3-13: Setting of T-200 transducer capsule assembly
A. Tab
B. Position 1
Maintenance and Troubleshooting Manual
Smart capsule setting
1
2
3
4
5
1
2
3
4
5
6
7
8
Emerson.com/Rosemount
00809-0600-3104