Additional Hardware Modes
3.3

Binary Counting Modes

Table 2
lists the modes available in binary counting mode.
Mode
Mode 0
2
External I
C Mode
LEDs: 00000
Mode 1
Auto-Calibration &
Diagnostics
LEDs: 00001
Mode 2
External PWM
LEDs: 00010
Mode 3
External PWM and Enable
LEDs: 00011
Mode 4
Analog Input
LEDs: 00100
Mode 5
Auto-resonance OFF
frequency adjust
LEDs: 00101
Mode 6
Life Test (RTP) 2s ON, 1s
OFF
LEDs: 00110
Mode 7
Life Test (RTP) Infinite Buzz
LEDs: 00111
Mode 8
Life Test (PWM) 2s ON, 1s
OFF
LEDs: 01000
Mode 9
Recorder
LEDs: 01001
Mode 10
Life Test (RAM) Infinite Buzz
LEDs: 01010
Mode 30
Actuator Break-in
LEDs: 11110
Mode 31
About the Board
LEDs: 11111
12
DRV2604 ERM, LRA Haptic Driver Evaluation Kit
Table 2. Binary Counting Modes
Button
Description
B1
Set ERM Output
B2
Set LRA Output
B3
Choose Trigger
B4
Trigger Button
B1
ERM Auto-Calibration
B2
LRA Auto-Calibration
B3
ERM Diagnostics
B4
LRA Diagnostics
B1
Disable PWM Mode
B2
Set ERM Output
B3
Set LRA Output
B4
-
B1
Return to normal mode
B2
Set ERM Output
B3
Set LRA Output
B4
-
B1
AC Coupling - ERM
B2
DC Coupling - ERM
B3
AC Coupling - LRA
B4
DC Coupling - LRA
B1
Alert (Auto-resonance On)
B2
Alert (Auto-resonance Off)
B3
Decrease output frequency
B4
Increase output frequency
B1
Begin Life Test
B2
Test Buzz
B3
Decrease output voltage (–1)
B4
Increase output voltage (+1)
B1
Begin Life Test
B2
Test Buzz
B3
Decrease output voltage (–1)
B4
Increase output voltage (+1)
B1
Begin Life Test
B2
Test Buzz
B3
Decrease output voltage (–1)
B4
Increase output voltage (+1)
B1
Start/Stop Recording
B2
Create Pattern
B3
Start/Stop Play Back
B4
-
B1
Life Test Infinite Buzz
B2
Life Test 2s ON, 1s OFF
B3
Decrease output voltage (–1)
B4
Increase output voltage (+1)
B1
Begin Actuator Break-in
B2
B3
B4
B1
Device ID
B2
Silicon Revision
B3
Code Revision
B4
Copyright © 2013, Texas Instruments Incorporated
Notes
Use this mode to control the DRV2604 using an external I2C Master. Press B1 or B2 to
choose between the ERM or LRA. Press B3 to choose the trigger type. (1 - Internal, 2 -
Ext. Edge, 3 - Ext. Level). Press B4 to trigger the waveform sequencer.
Run the auto-calibration. The new auto-calibration results are used for all board effects.
1 flash = successful, 3 flashes = error.
Run diagnostics. 1 flash = successful, 3 flashes = error. The status register bits [3:0]
are displayed on the mode LEDs [3:0] when complete.
External PWM - disconnect MSP430 PWM using JP1. Connect external PWM signal to
the "PWM" testpoint at the top of the board. Select actuator using buttons B2 and B3.
External PWM and Enable - disconnect MSP430 PWM using JP1. Connect external
PWM signal to the "PWM" testpoint at the top of the board. Connect an external enable
signal to the "EN" testpoint. Select actuator using buttons B2 and B3. Press B1 before
switching modes.
Analog Input - apply an external analog signal for AC coupling on the "Audio" jack.
Apply a DC coupled signal to the "PWM" testpoint.
Vary the auto-resonance OFF (open-loop) output frequency and see the change in
vibration force over frequency. Hold B3 or B4 for quick frequency adjustment. Compare
B2 (auto-resonance off) with B1 (auto-resonance on).
Life Test using RTP (2 seconds on, 1 second off) - life test repeats infinite times and
board must be powered down to stop. Increment / Decrement amplitude using B3 and
B4. Test new amplitude using B2. Choose actuator using buttons B1 and B2 in Mode 0
or Mode 1.
Life Test using RTP (Infinite Buzz) - board must be powered down to stop buzz.
Increment / Decrement amplitude using B3 and B4. Test new amplitude using B2
before beginning life test. Choose actuator using buttons B1 and B2 in Mode 0 or
Mode 1.
Life Test using PWM (2 seconds on, 1 second off) - life test repeats infinite times and
board must be powered down to stop. Increment / Decrement amplitude using B3 and
B4. Test new amplitude using B2. Choose actuator using buttons B1 and B2 in Mode 0
or Mode 1.
Recorder - use this mode to create a single amplitude pattern. Start by pressing the
record button (B1). Then use B2 to create the pattern by tapping the button. When
finished press the play back button (B3).
Life Test (RAM Mode) - Increment / Decrement amplitude using B3 and B4. B1 -
Start/Stop Infinite Buzz Life Test. B2 - Start/Stop 2s ON, 1s OFF life test. Choose
actuator using buttons B1 and B2 in Mode 0 or Mode 1.
Actuator Break-in - used to break in new actuators
About the Board - the value will appear on the mode LEDs in binary.
DRV2604 Device ID = 00100