4-2. Measurement List

This section explains how to check the measurement data of the temperature sensors, humidity sensors, and
metering devices.
Click [Monitor/Operation] in the menu bar, and then click [Measurement List] to access the Measurement List
screen.
Note: An AI controller (PAC-YG63MCA), a commercially available temperature sensor, and a humidity sensor are required to
measure the temperature and humidity.
Note: A commercially available pulse-output metering device is required to measure the electric, water, heat, and gas
consumptions using a built-in PI controller or PI controller (PAC-YG60MCA).
Note: A PI controller (PAC-YG60MCA) is not required when the built-in PI controller is used.
Update
Click to show the most
recent measurement data.
Measurement item
Measurement value
Item
Update
Measurement value
Number of units whose filter
sign is turned on
*1
Number of units in error
*1 The item will not appear if the number of units is "0."
WT07139X02
Click to show the most recent measurement data.
When [Auto] is selected, the measurement data is updated automatically every minute.
The current measurement values will appear.
Note: The following icons are used to indicate the measuring devices. Icons will appear in
orange when the measurement value reaches the upper or lower alarm threshold
value that has been set on the Measurement screen, accessible via the Web Browser
for Initial Settings.
Temperature sensor
Humidity sensor
Metering device
*1 When there is a communication error, the measurement value of the temperature or
humidity sensor will be "--."
*2 When there is a communication error, the measurement value of the metering device will be
the measured value immediately before the error detection.
The number of units under the control of AE-200/AE-50/EW-50 whose filter sign is
currently turned on will appear. Clicking "
section 4-4.)
Note: This item will not appear if the [Filter Sign Display] is set to [OFF] on the Basic
System settings screen, accessible via the Web Browser for Initial Settings.
The number of units under the control of AE-200/AE-50/EW-50 that are currently in error
will appear.
*1
Clicking "
" will bring up the Malfunction List screen. (See section 4-3.)
Description
Upper/lower alarm
Normal
threshold value is
" will bring up the Filter Sign List screen. (See
25
Number of units whose
filter sign is turned on
Number of units in error
Communication
error/sensor error
reached.
*1
*1
*2