If you have questions about how to install or operate the fixture safely, please contact
Harman Professional Technical support:
For technical support in North America, please contact
HProTechSupportUSA@harman.com
Phone: (844) 776-4899
For technical support outside North America, please contact your national distributor.
Protection from electric shock
The fixture has an ingress protection rating of IP20 and is for use in dry locations only. Do
not expose it to rain or moisture.
The fixture accepts AC mains power at 100-240 V~ (nominal), 50/60 Hz. Do not connect the
fixture to mains power that is not within this range.
The fixture has a maximum total power consumption of 180 W.
The fixture draws a maximum total current of 2.0 A at 100-120 V~ and a maximum total
current of 0.9 A at 200-240 V~.
The fixture draws a typical half-cycle RMS inrush current of 3.5 A for the first 10 milliseconds
when mains power is first applied to the fixture at 230 V~, 50 Hz.
The voltage and frequency at the power throughput socket are the same as that applied at
the power input socket.
Do not connect devices to power in a chain that will exceed the electrical ratings of any
cable or connector used in the chain.
If you relay power from one fixture to another using power throughput sockets, observe the
following safety limits, or you may create a risk of fire and electric shock:
Do not connect more than eight (8) MAC One fixtures in total to each other in an
interconnected chain when supplying the fixture with mains power from 100 V to 120 V.
Do not connect more than sixteen (16) MAC One fixtures in total to each other in an
interconnected chain when supplying the fixture with mains power from 200 V to 240 V.
To connect the fixture to mains power, you must first obtain 12 AWG or 2.5 mm
cable that is 16 A rated and heat-resistant to 90° C (194° F) minimum. In the USA and
Canada, the cable must be UL-listed, type SJTW or equivalent. In the EU, the cables must
be type H05VV-F or equivalent. Suitable cables with the correct connectors are available
from Martin.
Ensure that the fixture is electrically connected to ground (earth) via the power input cable.
Do not remove the protective coating on the housing or loosen screws to establish a
separate ground (earth) connection from the fixture's chassis.
Use only a source of mains power that complies with local building and electrical codes and
has both overload and ground-fault (earth-fault) protection.
Disconnect the fixture from AC mains power before carrying out any installation, cleaning or
maintenance work and when the fixture is not in use.
Isolate the fixture from power immediately if the power plug or any seal, cover, cable, or
other component is damaged, defective, deformed, showing signs of water ingress or
showing signs of overheating. Do not reapply power until repairs have been completed.
Before using the fixture, check that all power distribution equipment and cables are in
perfect condition and rated for the electrical requirements of all connected devices.
Do not connect a device to power if its maximum current draw will exceed the electrical
ratings of any cable or connector used in the chain.
Support the weight of cable runs. Do not allow a length of cable to hang from a connector.
Do not remove any cover from the fixture.
®
Martin
MAC One Safety and Installation Manual Rev. B
2