Example:
In this case, if the temperature set on the valve is 50°C, on Mondays, from 4
valve will increase by 5°C, or to 55°C, while in the hours from 7
00
00
between 17
and 22
it will increase to 57°C.
MODE 2 - in this mode, it is possible to program the temperature deviations in detail for all working days (Monday –
Friday) and for the weekend (Saturday – Sunday). To do this:
Select the option:
Select the part of the week for which change in the temperature settings is wanted
The further procedure is the same as in
Example:
PRESET
PRESET
In this case, if the temperature set on the valve is 50°C Monday to Friday, from 4
will increase by 5°C, or to 55°C, and in the hours from 7
00
00
between 17
and 22
‐ it will increase to 57°C.
During the weekend, from 6
00
00
17
and 22
‐ it will rise to 57°C.
➢ Factory settings – This parameter generates a return to the settings of a given valve saved by the manufacturer.
Restoring the factory settings changes the valve type to a CH valve.
Time
4
00
‐ 7
00
00
PRESET
7
‐ 14
00
17
‐ 22
Set Mode 2
Time
Monday - Friday
4
00
‐ 7
00
00
00
7
‐ 14
00
00
17
‐ 22
Saturday - Sunday
6
00
‐ 9
00
00
00
17
‐ 22
00
00
00
to 9
hours ‐ the temperature on the valve will rise by 5°C, that is to 55°C, and between
Temperature - Set
Weekly Control
Monday
+5°C
00
‐10°C
00
+7°C
00
00
to 7
00
00
to 14
, it will decrease by 10°C, so it will be 40°C, and
Mode 1
Temperature - Set
Weekly Control
+5°C
‐10°C
+7°C
+5°C
+7°C
00
to 7
00
to 14
‐ it will decrease by 10°C, so it will be 40°C, while
23
hours, the temperature set on the
00
‐ the temperature on the valve