CAUTION
If the
Boiler Protection
cases, the boiler may overheat, so it is recommended to configure the boiler protection settings.
For this type of valve, refer to the
Cooling - for controlling the temperature of the cooling system (the valve opens when the set temperature is lower
than the temperature of the valve sensor).
of valve is selected. This type of valve operates despite the active
selected shutdown threshold. This type of valve has a separate heating curve as a function of the
➢ Opening in CH calibration – When this function is enabled, the valve begins its calibration from the opening phase.
This function is only available when the valve type is set as a
➢ Floor heating - summer – This function is only enabled after selecting the valve type as
function is activated, the floor valve will operate in the
➢ Weather control – For the weather function to operate correctly, the external sensor cannot be positioned in an
location that is not exposed to atmospheric influences. The
switched on after installing and connecting the sensor.
CAUTION
This setting is not available in the
Heating curve - this is the curve according to which the set temperature of the controller is determined
on the basis of the external temperature. In order for the valve to operate properly, the set temperature
(downstream the valve) is set for four intermediate external temperatures: -20°C, -10°C, 0°C and 10°C.
There is a separate heating curve for the
temperatures of: 10°C, 20°C, 30°C, 40°C.
➢ Room regulator
Controller type
→ Control without room regulator - This option should be selected if the room regulator is to affect the operation
of the valve.
→ RS regulator decrease – This option is checked if the valve is to be controlled by a room regulator equipped
with RS communication. When this function is chosen, the controller will operate according to the
temp. lower
parameter.
→ RS regulator proportional - When this controller is chosen, the current boiler and valve temperatures can be
viewed. With this function checked, the controller will operate according to the
and
Setpoint Temperature Change
→ Standard room regulator - this option is selected if the valve is to be controlled by a two-state controller (not
equipped with RS communication). When this function is chosen, the controller will operate according to the
Room reg. temp. lower
Room reg. temp. lower - In this setting, the value by which the valve will lower its set temperature once the
temperature set in the room regulator is reached (room heating) is selected.
CAUTION
This parameter applies to the
Room temperature difference - This setting determines the unit change in the current room temperature (to
the nearest 0.1°C) at which a specific change in the set temperature of the valve will occur.
is off, the CH temperature will not affect the opening of the valve. In extreme
Return Protection Screen.
Boiler protection and Return protection
Summer
Cooling
and
parameters.
parameter.
Standard room regulator
20
Summer
mode, while the pump operates via the
CH
Valve.
Mode.
Weather sensor
function in the controller menu is
Return Protection
Modes.
Cooling
mode, and this is set for intermediate outdoor
and
RS regulator decrease
do not function when this type
Weather
sensor.
Floor
Valve. When this
Room reg.
Room Temperature Difference
functions.