Nautilus R614 Service Manual page 11

Hide thumbs Also See for R614:
Table of Contents

Advertisement

1.
All segments on
3.
Set individual segments one at a time until all segments are illuminated.
15 . The Console will display the Power-Up Mode screen.
Console Service Mode – x616 series (MY17) Consoles
The Console Setup Mode lets you input the date and time, set the units of measurement to either English or Metric,
service technician use only).
1.
To go into the Console Setup Mode, hold down the PAUSE/END button and Increase ( ) button together for 3 sec-
onds while in the Power-Up Mode.
Note:
2.
The Console display shows the Date prompt with the current setting. To change, push the Increase/Decrease buttons
active value (month / day / year).
3.
Push OK to set.
4.
The Console display shows the Time prompt with the current setting. Push the Increase/Decrease buttons to adjust
(hour / minute / AM or PM).
5.
Push OK to set.
6.
The Console display shows the Units prompt with the current setting. To change, push OK to start the Units option.
Push the Increase/Decrease buttons to change between "MILES" (Imperial English units) and "KM" (metric units).
Note: If the units change when there is data in User Statistics, the statistics convert to the new units.
7.
Push OK to set.
8.
The Console display shows the Sound Settings prompt with the current setting. Push the Increase/Decrease buttons
to change between "ON" and "OFF".
9.
Push OK to set.
10. The Console display shows the TOTAL RUN HOURS for the machine.
To enter the Manufacturing Menu (MFG Menu), hold down the PAUSE/END button and Increase ( ) button together
for 3 seconds while in the Power-Up Mode.
options. Push OK to make a selection.
series of tests similar to the tests listed below, but optimized to be run on the production line. This chained test
should not be used anywhere but on the production line.