PROGRAMMING
9
FACTORY
DEFAULTS
The panel is now programmed to its factory settings as shown below.
Master User code
E
1234
(0000-9999)
Limited User code
:
5678
(0000-9999)
Engineer code
:
9999
(0000-9999)
The following key applies to the table below:
E
= Entry/exit zone
A
= Access zone
i
= Immediate
zone
fe)
= Omitted zone (not active)
Zone number
Full set
Part set 3
9.2
Entering
Engineer
Mode
key QO YOO
The fault LED will flash when the Paragon Super is in Engineer mode.
The day LED will flash during programming of any of the functions.
Whilst in Engineer mode, you are able to remove any covers without creating a tamper
alarm.
9.3
Setting
Part-Set
Volume
Control
The Paragon Super has been designed with a unique feature enabling the customer to
have a reduced volume tone on part-setting of the control panel.
This volume is controlled via the adjustable volume pot on the main processor board.
1. Remove lid.
2. Set volume pot to desired volume
3.Depressed a number
key to check desired volume has been reached.
4.Replace cover.
This volume control can be overridden for full setting purposes by simply pressing
in the
4 digit Master or Limited User code. THe above only applies, when extension speakers
are being used. Each RKP has its own volume control pot.