C. ENGINEER FACILITIES
The engineer mode can only be accessed when the panel is in 'day' mode.
10.3.1
Entering
Engineer
Mode
Enter
@@
then
CHCHENES) Engineer code (Factory set 9999)
The fault light will flash for as long as the panel is in Engineer mode.
10.3.2
Leaving
Engineer
Mode
Enter
CIOWO)
then
CHCHENES) Engineer code (Factory set 9999)
This will return the panel to 'day' mode and the fault light will stop flashing.
10.3.3
Master
User
Facilities
The engineer has access to all the Master facilities but must prefix the function numbers
by (0)
Key sequences are as follows:
@M@)A) Chime on/off
@ OC) View event log
@®Q@DG) Clear event log
@®@G) Change Limited User code
@®@©®) Change Master User code (A)(O)(6) Enter System Test Mode
@O)@ Enter walk Test Mode
11
LED
FUNCTION
Panel light on
;
Indicates there is mains on the system
RKP supply light on
:
Indicates DC supply to RKP
Day light on
:
Indicates the system is off. (Day mode)
Fault light on
:
Blown Auxiliary fuse
or
Blown Bell fuse
or
Mains Supply disconnected
Alarm light flashing
:
Indicates an Alarm activation
Tamper light flashing
;
Indicates a Tamper alarm
P.A light flashing
:
Indicates a Personal Attack activation
Fire light flashing
5
Indicates a Fire alarm activation
Fault light flashing
:
Engineer mode
Chime lighton
:
Chime is on - Entry/Exit circuits
of last set-mode used
20