2. Check 250mA fuse on mains input
terminal block. (Below transformer)
10. Panel Waiting for Further Commands.
Day LED will flash if you have started a function but not f
inished the sequence. e.g
a. Enter @) (2) (View Log)
Panel awaiting @) to terminate function.
b. @) (4) (Change Limited User code) Awaiting codes.
Ge ® (5) (Change Master User code) Awaiting codes.
d. @) (6) (Customer Test Procedure)
Use N° keys to scroll, @) to terminate.
11. Walk Test Mode.
Enter @) @) Chime Light will flash
Set Panel to desired set mode (Full, 1, 2 or 3)
Walk Test circuits.
Enter (xX) (Xx) (x) (x) (Master Code) to exit.
12.Chime Mode.
Enter @® 1) Chime Light will stay on.
The Paragon Super will remember its last Set Mode
e (Full, 1, 2 or 3).
Any zone programmed as Entry / Exit will chime
on going open circuit.
Enter @® 4) to terminate feature.
LED will clear.