Zones; Hour Zones - Pyronix PARAGON SUPER II Installation Instructions Manual

Table of Contents

Advertisement

6
ZONES
6.1
Engineer
Programmable
Zones
Entry / Exit
This is a zone which allows limited-time access to the
premises in order to set or unset the system.
Access
This is a zone which, on setting the panel, allows access
to the Entry / Exit zone. However, if the panel is set and
an Access zone is triggered before an Entry / Exit zone
then an alarm will be generated immediately.
Immediate
This is a zone which will, when entered, go into alarm
when the panel is set.
Omitted
If a zone is programmed as an Omitted zone by the
Engineer, then it is ignored by the panel. Primarily used
for Part set options. It also allows the user to continue to
use the alarm system even if a fault has been discovered
on one or more zones.
6.2
24 hour
zones
Personal
Triggering of the Personal Attack (P.A) zone will always cause a
Attack
full alarm activation regardless of whether or not
the panel is set.
Tamper
A tamper zone activation will only generate an internal
alarm, if the panel is in Day mode. If a tamper fault is
present and the panel is then set, the system will give a
second internal alarm. Triggering of a tamper zone when
the panel is set will always give an external as well as
internal alarm
Fire
Triggering of the fire zone will only operate the internal
sounder. A fire alarm is identified by a three note rising
sound which is easily distinguished from all other tones.
"The Fire Zone is intended as an extra feature to the Intruder Alarm system and
must not be regarded as a total fire protection system**
RDOC 279B issue 1