Enter
COG) (3) Volume will be determined by volume pot. i.e Reduced volume
10.1.3
Unsetting
the panel
The panel can be unset by entering the building via the entry exit route and then keying
either of the two user codes.
10.1.4
Activating
the
Personal
Attack Alarm
(PA)
To activate the Personal Attack Alarm enter
10.1.5
Activating
the
Fire Alarm
To activate the Fire Alarm enter CS) @)
10.1.6
Turning
Chime
On and Off
(Panel must be in 'day' mode)
Enter
The status of the chime facility is indicated by the 'chime' LED on the front of the control
panel. When the chime mode is selected a two tone chime will be produced
by the internal sounder and any extension speakers when an Entry / Exit zone is
activated. The same key sequence can be used to turn off the chime facility.
10.1.7
Reading
Event
Log
(Panel must be in 'day' mode)
enter @Q)
The 'day' led will flash and the most recent event stored in the log will be displayed. If the
up arrow key is pressed the previous log entry will be displayed. Similarly if the down
arrow key is pressed the next most recent entry will be displayed.
The event log can be scrolled backwards and forwards using the up and down arrow
keys to allow the last 18 events to be viewed.
To leave this function press the CS) key. An error tone will be produced if an attempt
is made to scroll outside either end of the event memory.
The table below shows the
symbols stored in the event log and their meanings.
E
Entry/Exit zone activation.The panel was not unset before
the end of the entry time period, or User did not leave in time.
| to 5
Activation of a programmable zone.
Eee
This shows the next event in the log has triggered the alarm
system.
This shows that a zone was omitted and refers to the
number which precedes it in the log.
Tamper fault or sabotage.
p
P
Personal attack activation.
F
Fire alarm activation.
RDOC 279B issue
17