OmniLogic Part Replacement
NOTE: This procedure is for replacing the Controller on OmniLogic units built AFTER 2023. Refer to
page 7 for units built before 2023.
Clone Controller to USB
NOTE: Requires OmniLogic firmware version R4.3.0 or greater. If OmniLogic is using an older firmware
version, upgrade before attempting this procedure. Before you begin this replacement, it is important
to save the current OmniLogic configuration to a USB thumb drive. Follow the procedure below to save
the configuration. NOTE: If a clone cannot be saved because the Controller is not operational, then
the OmniLogic will have to be reconfigured using the Configuration Wizard or restored from a copy
of the latest configuration available at www.haywardomnilogic.com after logging into your account.
Refer to page 13 for more information.
1.
Insert a USB thumb drive into the USB port on the bottom of the Controller.
2.
Navigate to the Config menu and press "Replace MSP".
SPA
90
F
º
71º F
air
3.
Press "Clone Controller to USB" and press the check mark at the bottom to start the clone. When
the clone is complete, press the check mark to finish and remove the USB thumb drive.
Clone Controller to USB
Restore Clone from USB
SYSTEM
Replace MSP
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
themes
con g
Wait
datalog
Replace MSP
SYSTEM
con guration
Backup Con guration to USB
Clone was successfully created
Internal Con guration
Backup
CONFIGURATION
backup
2 / 2
4
Need help?
Do you have a question about the HLXPLCONTROL and is the answer not in the manual?