matrix 1 led troubleshooting

1. EXIT LOOP
2. CENTER LOOP
3. SAFETY LOOP
ID plug MUST be plugged in.
4. 12 VDC
5. 24 VDC
6. SECONDARY LIMIT SWITCH ON-LINE
7. PRIMARY LIMIT SWITCH ON-LINE
Matrix 1 LED
Problem Condition
"ID PLUG" LED is FLASHING on Matrix 1 and
board beeping
"POWER" LED is OFF
"BATTERY IN USE" LED is ON
"BATTERY IN USE" and "POWER" LED are
FLASHING
PRIMARY "MOTOR ON-LINE" LED is OFF
SECONDARY "MOTOR ON-LINE" LED is OFF
PRIMARY "LIMIT SWITCH ON-LINE" LED is
OFF
SECONDARY "LIMIT SWITCH ON-LINE" LED is
OFF
"UL Entrap" LED is ON
"REVERSE SENSITIVITY" LED is FLASHING
"EDGE 1" LED is ON
"EDGE 1" LED is flashing
"EDGE 2" LED is ON
"EDGE 2" LED is FLASHING
MATRIX 1
BATTERY
BACK-UP MODE
LEAVE
CLOSED
MADE in USA
LEAVE
OPEN
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
OFF
CENTER
SAFETY
MIN
MAX
OFF
CLOSE TIMER
PARTIAL
OPEN
ID
PLUG
POSITION
MAX 1700FS
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
GND
Normal
LED
OFF
Insert ID PLUG module that is tethered to chassis into "ID PLUG" connector of Matrix 1.
15
ON
Check if AC POWER ON/OFF SWITCH is ON.
21
Check 24 V wiring from MC-200 PRIMARY.
OFF
AC power is lost, operator is in battery back-up mode.
20
Check if AC POWER ON/OFF SWITCH is ON.
Measure power input DC voltage on Matrix 1 ("24V/GND" - 2-pin black connector), (expected reading
34 VDC if AC on, 25VDC if on battery back-up).
OFF / ON
Battery not plugged in to BATTERY IN port on battery charger (BC-7 module)
20 / 21
ON
Check wiring between Matrix 1 RS485 (+,-, gnd) and PRIMARY MC-200 RS485 (+,-, gnd) terminals,
9
connect [(+) to (+)], [(-) to (-)] and [GND to GND]
ON
Check wiring between Matrix 1 RS485 (+,-, gnd) and SECONDARY MC-200 RS485 (+,-, gnd) terminals,
8
connect [(+) to (+)], [(-) to (-)] and [GND to GND].
ON
Check if limit switch box is plugged into PRIMARY MC-200 "LIMIT SWITCH" input on back and MC-200
7
is powered ON.
ON
Check if limit switch box is plugged into SECONDARY MC-200 "LIMIT SWITCH" input on back and
6
MC-200 is powered ON.
OFF
An entrapment event has occurred, check if an entrapment sensor was triggered (see if EDGE 1,
16
EDGE 2, or PHOTOCELL LED is on).
OFF
An ERD event may have occurred. Check for gate obstruction.
17
ERD sensitivity is too high for application. Re-adjust ERD setting on MC-200, (see
OFF
Sensor on EDGE 1 input (photocell or edge) may have detected an obstruction while closing gate.
13
Photocell on EDGE 1 input is misaligned with reflector.
OFF
Sensor on EDGE 1 input (photocell or edge) may not be wired properly, (see
13
Sensor is NOT a N.C. monitored sensor that is UL325 2016 compliant.
Sensor is damaged or malfunctioning.
Sensor might need to be re-learned.
OFF
Jumper between EDGE 2 and GND is missing or broken (jumper is required if a sensor is not present).
14
Sensor on EDGE 2 input (photocell or edge) may have detected an obstruction while opening or closing
gate.
Photocell on EDGE 2 input is misaligned with reflector.
OFF
Sensor on EDGE 2 input (photocell or edge) may not be wired properly, (see
14
Sensor is NOT a N.C. monitored sensor that is UL325 2016 compliant.
Sensor on EDGE 2 is damaged or malfunctioning.
Sensor might need to be re-learned.
Table continued on next page
PRIMARY
GATE
MAGLOCK
DELAY
OPEN
OPEN
OPEN
MAG
LEFT
RIGHT
1 TIME
OFF
1.5Sec
2Sec
LOCK
Tamper NO
EXIT
CENTER
SAFETY
GATE
TAMPER
Tamper IN
PHOTOCELL
UL
ENTRAP
ID PLUG
MOTOR MOTION
UL ALARM 12V
ALARM RET
OPEN
STOP
CLOSE
MAX
REVERSE SENSITIVITY
GATE SPEED
MOTOR OVERLOAD
GATE
MIN
NO LIMIT SWITCH /
STATUS
CLAMP SLIPPING
MAX
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
SEC
GATE
GATE
8. SECONDARY MOTOR ON-LINE
9. PRIMARY MOTOR ON-LINE
Solution(s) for
Problem Condition
14
COM
10. MAGLOCK
NC
11. GATE TAMPER
COM
GND
12. PHOTOCELL
13. EDGE 1
EDGE 1
14. EDGE 2
EDGE 2
15. ID PLUG ERROR
ERROR
16. UL ENTRAPMENT
RESET
GND
17. REVERSE SENSITIVITY
18. MOTOR OVERLOAD
OPEN
19. NO LIMIT SWITCH
COM
CLOSE
CLAMP SLIPPING
20. BATTERY IN USE
BATTERY
IN USE
21. POWER
POWER
22. GATE DISABLE
7
7
UL 325 2016 Standard-MAX 1700FS Quick Install Rev 3
).
8
).
).

Advertisement

Table of Contents
loading

Table of Contents