Max 1700FS Quick Install Manual page 9

Fail safe slide gate operator
Table of Contents

Advertisement

7
continued
Entrapment Protection Device
Locations:
OPENING Direction
Photocell
Outside Property
Gate Closed
Inside Property
Sensing Edges
Wireless
Module
CLOSING direction
10K NORMALLY CLOSED
Sensing Edge Wirelessly
WIRELESS NOTE: Refer to the
instruction sheet that comes
with the wireless module for
wiring and mounting instructions
when using wireless option.
IMPORTANT:
Protection Photocells MUST be
Monitored Normally Closed Type.
OPENING direction 10K
NORMALLY CLOSED Sensing Edge
Wireless Module
Gate Closed
OPENING direction
Sensing Edge
Gate Closed
If a self-supporting post is being used, then sensing edges need to
be installed on EACH side of the post to protect against entrapment
in the OPENING and CLOSING direction of gate travel.
Photocell Beam Height
Install photocells on either side of
gate, as close as practical to the
gate but no further away than 5".
Outside
Property
Beam Height:
21" for most
Entrapment
installations but No
higher than 27.5"
above ground.
Wall
Beam: 5" or LESS from OPEN gate.
Entrapment Area
Run conduit to operator
OPENING direction photocell to
MC-200 motor controller, Monitored.
Normally CLOSED (N.C.)
NOTE: Connect to Photo Cell input on MC-200.
Wireless
Module
Self-Supporting Post
CLOSING direction Sensing Edge
Wireless
Module
7
5"
5"
or
or
Less
Less
Illustrations not to scale
Photo Beam
IMPORTANT:
be in alignment or fault will occur.
Wall
OPENING direction10K NORMALLY CLOSED Sensing Edge Wirelessly
IMPORTANT:
Sensing edges MUST be
Monitored 10K Normally Closed Type.
OPENING
OPENING
direction
direction
Sensing
Sensing
Edge
Edge
UL 325 2016 Standard-MAX 1700FS Quick Install Rev 3
Inside
Property
Photocells MUST
CLOSING direction
Sensing Edge
OPENING
direction
Sensing
M G
L- TX
M on
20
ito
G at
re d
e Li
Edge
nk
M ill
er Ed
(Wireless)
ge