Max 1700FS Quick Install Manual page 21

Fail safe slide gate operator
Table of Contents

Advertisement

emx irb-mon
Transmitter
(TX)
CLOSING direction Thru-Beam
To Motor Controller
PWR 12V Input
Transmitter (TX)
TX
Green
POWER INPUT
LED
TRANSMITTER
BOARD (TX)
IMPORTANT:
Motor Controller or they will NOT be MONITORED.
NOTE: To meet the UL 325 2016 standard, Type B1 Non-Contact sensor
entrapment protection device MUST be MONITORED by the gate operator.
Photocell (Thru-Beam) CLOSING Direction
Single Gate Operator
Receiver
To Motor Controller
(RX)
EDGE 1 and PWR 12V Input
Gate Closed
Single
Operator
Installation Steps:
1. Set DIP-switches on receiver.
2. Install jumper on receiver.
3. Wire 12V motor controller
power to receiver.
4. Wire motor controller EDGE 1
to receiver photocell NC.
Wire motor controller GND to
receiver photocell COM.
5. Wire 12V motor controller
power to transmitter.
6. Align photocells.
7. Adjust sensitivity on receiver.
Photocells MUST be powered by
T X
Sensitivity Adjustment:
If the photocell does not
respond to an obstruction,
lower the sensitivity by
turning adjustment
counter-clockwise.
DIP-switches:
1, 2, 3 are OFF.
Switch 4 is ON
If trouble occurs, try
turning switch 4 OFF.
NOTE: Power must be
cycled when switches
are changed.
Jumper MUST be on Com-NC.
MOTOR
2
3
Inputs
&
MUST be "LEARNED"
to MONITOR sensors.
To LEARN inputs
1. MONITORED Sensors MUST be
wired to inputs BEFORE they can be
learned. Any unused inputs MUST be
jumpered.
2. Reversing Edge and/or Photo Cell can
be wired to either input 2 or 3.
3. Press and HOLD the OPEN & STOP
buttons at the same time on Matrix 1
MAX
until beep is heard, learn mode begins.
MOTOR MOTION
Motor Controller
OPEN STOP
Learn mode lasts for 5 min. indicated
by beeping.
4. LEDs WILL be ON for each detected
sensor on MC-200. LEDs WILL be ON
for BOTH MC-200s when dual
operators are used.
5. Press STOP button again within 5 min.
to learn sensors and end learn mode,
beeping stops.
Inputs are now MONITORED.
Entrapment Protection
Inputs:
Jumper UNUSED Entrapment
Protection Inputs to GND or
a fault will occur.
19
IMPORTANT:
in alignment or fault will occur.
Green LED will remain ON receiver
when in proper alignment.
R X
Receiver (RX)
RX
NO
COM
NC
NC
COM NO
JUMPER
N O
C o
RECEIVER
m N
BOARD (RX)
C
PWR 12V
Polarity does NOT matter
MOTOR
BATTERY
LIMIT
ALARM
Power In
PACK
SWITCH
INPUTS
ONLY power entrapment protection
sensors with MC-200 PWR 12V
2
&
3
:
MC-200
PWR 12V
MUST be used
Entrapment Protection
Sensor Guidelines
A sensor MUST be wired to
operator WILL NOT function.
Monitored
Wire NORMALLY CLOSED (N.C.)
Reversing
MONITORED sensors ONLY, to each
Edge
operator's MC-200 when dual operators
CLOSE
OR
are used.
Reversing Edge and/or Photo Cell can
Monitored
be wired to ANY of the 3 Inputs.
Photo
Cell
MC-200
PWR 12V
power MONITORED sensors.
UNUSED inputs MUST remain
JUMPERED or fault will occur.
CAUTION:
See installation instructions.
MUST jumper
ATTENTION:
Voir la notice d'installation.
1
unused inputs
3
2
UL 325 2016 Standard-MAX 1700FS Quick Install Rev 3
Photocells MUST be
Green
LED
SENSITIVITY
POWER
EARTH
INPUT
GND
Common-GND
Normally Closed
Edge 1
MATRIX 1
EDGE 1
or
MUST be used to