Adjust Erd Reverse Sensor; Loops & Loop Detectors - Max 1700FS Quick Install Manual

Fail safe slide gate operator
Table of Contents

Advertisement

8

Adjust ERD Reverse sensor

The ERD Sensor - Electronic Reversing Device (Type A) MUST be adjusted for the OPEN and CLOSE gate cycles.
When the gate encounters an obstruction during the CLOSE cycle, it will reverse to the open position and PAUSE the gate.
An input command (press remote button or exit loop) is needed BEFORE the gate will reset and close again.
When the gate encounters an obstruction during the OPEN cycle, it will reverse approximately 6 inches and PAUSE the gate.
An input command (press remote button or exit loop) is needed BEFORE the gate will reset and open again.
For the ERD Sensitivity to function correctly:
Virtual limit sensors must be programmed BEFORE adjusting the ERD Sensitivity.
Typical Settings:
15 14 13
16
12
MAX
Position 13:
LED ON
3
Typical gate setting.
4
5
ERD
Sensitivity
15 14 13
Position 16:
16
12
MAX
Heavy gate setting.
LED ON
3
Long gate setting.
4
5
Cantilever gate setting.
ERD
High wind area gate setting.
Sensitivity
CAUTION:
MAXIMUM force before reversing direction.
9
loops & loop detectors
In-Ground Loops
Connections
Safety Loops
Wired in series
NOTE: See manual for
more information
about loops and
loop detectors.
Limit SW
PhotoCell Edge
2
POWER
1
Edge
UL
MATRIX
MC-200
ON-LINE
Entrap
Motor Controller
IMPORTANT:
with ERD adjustment, cycle
the gate 3 or 4 times to make
sure that the ERD sensor does
not falsely trigger during
normal gate operation.
Re-adjust if this happens.
Position 16 results in gate exerting
MATRIX 1
BATTERY
PRIMARY
BACK-UP MODE
GATE
LEAVE
CLOSED
LEAVE
OPEN
OPEN
OPEN
MADE in USA
LEFT
RIGHT
OPEN
1 TIME
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
CENTER
SAFETY
EXIT
ON
OFF
CENTER
SAFETY
MIN
MAX
OFF
CLOSE TIMER
PARTIAL
MOTOR MOTION
OPEN
ID
PLUG
OPEN
STOP
POSITION
RECORDER
MAX
REVERSE SENSITIVITY
12VDC
GATE SPEED
MOTOR OVERLOAD
GND
OBD PORT
BLACK BOX
MIN
NO LIMIT SWITCH /
24VDC
CLAMP SLIPPING
MAX
GND
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
SEC
GATE
GATE
MAX
LED ON
JOG
JOG
LEFT RIGHT
Sensitivity
MAX
LED ON
When satisfied
Sensitivity
MAX
LED ON
Sensitivity
If alarm sounds while adjusting ERD,
press STOP BUTTON on Matrix 1 to
shut-off alarm.
MAGLOCK
DELAY
MAG
OFF
1.5Sec
2Sec
LOCK
COM
NC
Tamper NO
GATE
COM
TAMPER
GND
Tamper IN
PHOTOCELL
UL
EDGE 1
EDGE 2
ENTRAP
ID PLUG
ERROR
UL ALARM 12V
ALARM RET
E D
RESET
I
CLOSE
T e l:
4 8 0
D E
.9 6
O N
F L
GND
E C
8 .6
5 =
O p
T O
4 0 7
ti m
M E
= In
T E
cr e
u m
1
= D
S e
R
2
e cr
a se
n s.
S e
S W
3
L E D
e a
n s.
1
se
O N
P O
IN D
S e
S W
n s.
O N
W E
IC A
O N
O N
R
T O
O F
= N
O F
O F
R S
F
F =
F =
o rm
O F
O N
D E
N o
a l
F
T E C
S W
O F
O N
P o
P o
3
F =
T
w e
w e
O N
O F
= D
r
r
F =
e te
O F
= F
2 H
F =
N o
ct
a il
OPEN
z Fl
D e
S W
F a
GATE
L o o
as h=
te ct
4
p F
O N
S W
1 F
D el
la sh
a u
ay
O N
O N
2 Fl
lt
Ti m
as he
= O
in g
O F
3 Fl
F
O F
COM
s=
p e n
O F
F =
STATUS
as he
S ho
L o o
F
O N
s= 25
rt ed
p
S W
O F
B ot
% ch
Lo op
6
F =
h LE
of In
O N
C ur
D 's
an ge
du ct
O F
= 2
P W
re nt
Fl as
F =
CLOSE
R LE
Lo op
hi ng
an ce
S W
S e
N o
P re
D Fl
=
O N
7
vi ou
as hi
Fa ul
t
s Lo
ng =
O F
= N
op
F =
o rm
Fa ul
S W
8
In fi
t
O N
O F
= S
F =
e n
N o
BATTERY
IN USE
POWER
8
15 14 13
16
12
16 sensitivity setting positions.
ERD
3
Motor
NO mechanical hard stop for knob.
4
5
OverLoad
ERD
Adjusting ERD:
15 14 13
16
12
A. Turn knob until blue LED lights up.
3
4
Maximum sensitivity reached,
5
Position 1 - Too sensitive for most gates.
ERD
B. Turn knob counter-clockwise to
15 14 13
16
12
reduce gate sensitivity while testing ERD
until desired results is attained.
3
4
(LED remains OFF for all but position 1)
5
ERD
r
w e
n a l
P o
m i
T e r
Wire to
Power Terminal
a l
back of
e r n
E x t
o p
MAX External Loop Detector
detector
L o
t o r
t e c
Cable Adapter Sold separately
D e
External Loop Detectors
NOTE: DO NOT select the PULSED output
option for Loop Detectors.
O
N
1
2
3
4
5
6
7
8
8 0 0
NOTE: DO NOT set Loop Detectors to
A 1
4
L M
5
2
6
N S
F re
7
S E
= L
q u
8
o w
e n
cy
M e
= M
d iu
HIGH sensitivity to avoid false trigger.
e d
m -L
H ig
iu m
o w
-H ig
h
h
S e
cu re
il S
R
a fe
T E
5
M E
O u
T O
tp u
= P
E C
u ls
t B
F L
e o
D E
B sa
n E
N S
= P
m e
u ls
n tr
S E
a s
y
L o
e o
A
o p
n E
F a
xi t
u lt
co n
W E
R
d D
D e
P O
la y
e la
y
C T
T E
I
a l
E D
Plug-In Loop Detectors
n it
P re
D E
e P
se n
re se
ce
si ti
n ce
vi ty
S e
n si
B o
ti vi
o st
T
S E
ty B
R E
o o st
UL 325 2016 Standard-MAX 1700FS Quick Install Rev 3
Matrix 1
MOTOR MOTION
STOP
OPEN
CLOSE
Com, Gnd (Black)
Loop Detect
Output (White)
Power 15 VDC
(Red)

Advertisement

Table of Contents
loading

Table of Contents