MAX 1500 PRO/2200 PRO/f18 PRO
MATRIX III
CONFORMS TO UL STD 325
CONFORMS TO UL STD 325
MAX 1500 PRO/2200 PRO UL CLASS - I, II, III, IV
MAX F18 PRO UL CLASS - III, IV ONLY
CERTIFIED TO CAN/CSA STD
C22.2 NO. 247
Brushless DC Slide Gate Operators
Version 7a
Residential/Commercial
Made in USA
www.max.us.com
Installation Guide for
Slide Gate Operators
SAFETY SENSORS REQUIRED
4009963

Advertisement

Table of Contents
loading

Summary of Contents for Max 1500 PRO

  • Page 1 Slide Gate Operators MATRIX III CONFORMS TO UL STD 325 CONFORMS TO UL STD 325 MAX 1500 PRO/2200 PRO UL CLASS - I, II, III, IV SAFETY SENSORS REQUIRED MAX F18 PRO UL CLASS - III, IV ONLY CERTIFIED TO CAN/CSA STD C22.2 NO.
  • Page 2 Exception : Les commandes d’accès d’urgence accessibles au personnel autorisé seulement (p. ex. pompier, policier, SMU) peuvent être placées à tout endroit dans le champ de visibilité de la barrière. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a Safety - 1...
  • Page 3 7) One or more contact sensors shall be located at the bottom edge of a vertical barrier (arm). 7) Au moins un capteur de contact doit être situé sur le bord inférieur d’une barrière verticale (bras). UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a Safety - 2...
  • Page 4 7. La voie d’accès est réservée aux véhicules seulement. Les piétons doivent utiliser une voie d’accès différente. 8. SAVE THESE INSTRUCTIONS. 8. CONSERVEZ CES INSTRUCTIONS. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a Safety - 3...
  • Page 5 B2 - Provision for connection of a contact sensor (edge device or the equivalent). E - An audio alarm. B1 and B2 means of entrapment protection must be MONITORED. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a Safety - 4...
  • Page 6 A minimum of TWO entrapment protection sensors MUST be installed, ONE in EACH direction of gate travel or operator will NOT function. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a Safety - 5...
  • Page 7: Table Of Contents

    - UL 325 Type A Inherent (ERD sensor) 7 1/2” - Inputs for NORMALLY CLOSED (N.C.) and 10K Type UL 325 Type B1 (photocell) 19” 14 1/2” and Type B2 (sensing edge) UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 8: Step-By-Step Installation

    Concrete Pad Concrete Depth Note: The heavier the gate, the deeper the concrete pad should be. At least two feet recommended for heavier gate. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 9: Connect Chain To Gate (Standard)

    Chain 7.5” 7.5” Bracket position 13.5” 13.5” Concrete Pad 6” DO NOT mount chain Operator in Front Position (Standard) bracket too high on gate. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 10: Rear Mounting Position (Alternate)

    Concrete Pad Concrete Depth Note: The heavier the gate, the deeper the concrete pad should be. At least two feet recommended for heavier gate. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 11: Connect Chain To Gate (Rear Pos)

    Approx.1.5” and existing chain exit slot. 16.5” Make sure cuts are plumb with existing Remove chain exit slot. Existing chain exit slot. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 12: Ac Input Power

    DO NOT O f f T u r CYCLE OPERATOR! LEDs should light up on operator. Battery power automatically turns ON. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 13: Ground Operator

    SECONDARY LINK BEFORE cycling NOTE: PRIMARY board settings will override secondary operator. board settings if a conflict in settings occurs. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 14: Entrapment Protection Wiring

    Beam: 5” or LESS from OPEN gate. Photo Beam Entrapment Area Conduit IMPORTANT: Photocells MUST be in alignment or fault will occur. Inside Property Continued on next page. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 15 Unlearned Input NOTE: If STOP button is not pressed within 5 min. learn mode automatically end after 5 min. 10K Sensing Edges OPEN STOP CLOSE UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 16: Program Virtual Limit Sensors

    The PROGRAM LED will turn OFF, the GATE OPEN LED will turn ON and stay on and the beeping will stop. Virtual OPEN limit is programmed. Push CLOSE button and the operator will function normally. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 17: Learn Gate Positions

    If alarm sounds while adjusting ERD, CAUTION: Position 16 results in gate exerting press STOP BUTTON to shut-off alarm. STOP OPEN CLOSE MAXIMUM force before reversing direction. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 18: Loops & Loop Detectors

    Turned ON - (In-ground loops required) OPENING gate PRIMARY/ the speed set on “ GATE SECONDARY LINK will stop and close after vehicle clears safety loop, SPEED” settings. preventing UNAUTHORIZED entry. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 19: Wiring Opening Device Options

    NOTE: If STOP button is not pressed within 5 min., learn mode terminates. OPEN STOP CLOSE If no “LEARNED” sensors are detected then factory default setting is restored (Inputs will NOT be Monitored). UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 20: Additional Features

    OPEN/CLS 12VDC OUTPUT 12VDC OUT Set desired features using DIP-switches. Dual Gate Operators NOTE: Primary operator DIP-switch settings ONLY (settings ignored on secondary Matrix III) UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 21: Gate Shut-Off Switch

    KEY availability. Slide door open Turn and HOLD key either way and insert key. for reversible gate directions. Jog Switch UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 22: Gate Tamper Feature

    Alarm Reset Button Gate Tamper LEDs UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 23: Dropping The Chain - Gate Tamper Is Armed (On)

    The alarm reset button MUST be pressed to turn OFF the alarm and reset the operator. If GATE TAMPER relay is connected to an existing building alarm system, then they will get a triggering of their alarm system and should be notified of the situation. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 24: Dual Gate Operators Wiring

    Three RS-485 Wires (See above) Secondary Operator Primary Operator Alarm Shut-OFF MOTION CONTROL NOTE: The Alarm Shut-Off “STOP” button can be pressed on EITHER gate operator. OPEN STOP CLOSE UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 25: Gate Disable Feature

    When RADIO Input gets activated: Gate opens and GATE TAMPER relay will activate after 3 min. This allows time to turn OFF GATE DISABLE or disarm an existing building alarm system if connected. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 26: Troubleshooting

    SECONDARY LINK 1. Plug MAX USB flash drive into OBD port. OBD LED will flash while file is downloading. Remove flash drive after LED stops flashing (up to 5 minutes to download). 2. Plug flash drive into any computer USB port OR smart phone using a USB phone adapter.
  • Page 27: Gate Cycling Troubleshooting

    Check if any loops are active, check SAFETY LOOP or EXIT LOOP LED is ON. • Check if any open command inputs are active (check if LED is ON on for: RADIO, FIRE DEPT, MAX OPEN, STRIKE, KEYPAD/RDR). Check device connected to the input that LED light is turned ON.
  • Page 28: Matrix Iii Led Troubleshooting

    “PROGRAM” LED is FLASHING • Program button has been pressed and programming mode is active. Press button again to leave programming mode. Table continued on next page UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 29 Check if OPEN and CLOSE Limits have been learned. Refer to “Learn Gate Positions” (see slowly. • ONLY Maximum settings will turn LEDs ON. All other settings, LEDs remain OFF. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 31: Emx Irb-Mon Single Gate

    OPEN/CLS 12VDC OUT NOTE: To meet the UL 325 2018 standard, Type B1 Non-Contact sensor entrapment protection device MUST be MONITORED by the gate operator. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 32: Emx Irb-Mon Dual Gates

    NOTE: To meet the UL 325 2018 standard, Type B1 Non-Contact sensor Matrix III or they will NOT be MONITORED. entrapment protection device MUST be MONITORED by the gate operator. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 34: Wiring Overview

    Card Reader Keypad Reset Button Stop Dry Contact Safety Opening Device Key Switch Manual Release Secondary Operator RS-485 Communication see page 17 Manually Releases Slide Gate UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 35: Optional Magnet Limit Sensors

    7. JOG gate closed slightly and install magnet. buttons accordingly to move the gate (release the button to stop gate). 8. Gate positions can now be learned, see UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 36: Optional Solar Power

    LINK 24 V Batteries PRIMARY/ DANGER Use AGM battery type. SECONDARY LINK Use insulated tools and avoid HAZARDOUS CURRENT placing metal objects near the batteries. UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 37 UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 38 UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 39 UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7a...
  • Page 40 MATRIX III www.max.us.com CONFORMS TO UL STD 325 MAX 1500 PRO/2200 PRO UL CLASS - I, II, III, IV SAFETY SENSORS REQUIRED MAX F18 PRO UL CLASS - III, IV ONLY CERTIFIED TO CAN/CSA STD C22.2 NO. 247 Residential/Commercial Brushless DC Slide Gate Operators...

This manual is also suitable for:

2200 proF18 pro

Table of Contents