Dual Gate Operators Wiring - Max 1700FS Quick Install Manual

Fail safe slide gate operator
Table of Contents

Advertisement

dual gate operators wiring

Reflector
AC input
power
Secondary Operator
NO Matrix 1
Secondary Operator
MC-200
P h
o t o
P O
C e
ll E
W E
M C
d g
R
e
L im
- 2 0
M o
2
it S
t o r
W
0
U L
C o
E n
1
n t r
t r a
E d
p
o l l
g e
e r
M A
T R
O N
I X
- L I
N E
J O
M A
G
L E
L E
X
F T
D
J O
O N
G
R I
G H
T
Jumper ALL Entrapment
Protection Inputs to GND
on Secondary MC-200
when ONLY using
CLOSE photocell.
AC input power to EACH gate operator.
Entrapment protection (CLOSE photocell) to PRIMARY GATE OPERATOR MC-200.
- Jumper any UNUSED entrapment protection inputs to GND on BOTH MC-200s or a fault will occur.
- See manual if installing more entrapment protection devices than just a CLOSE photocell.
Opening device to the PRIMARY GATE OPERATOR.
Matrix 1 Open Left - Open Right set for the PRIMARY GATE OPERATOR opening direction.
(Secondary operator automatically set to opposite opening direction)
OPTIONAL - In-ground loop wires to the PRIMARY GATE OPERATOR.
NOTE: The Alarm Shut-Off is located on the Primary gate operator ONLY.
To Secondary MC-200 Edge 2 or Photo Cell Input
Three RS-485 Wires to Matrix 1 (See below)
NOTE: See Megatron manual for more information
about Dual Gate Operator installation.
1 6 1 5 1
4
1 3
1 2
3
4
E R
5
D
E R
S e
D
M o
n s
O v
it iv
t o r
it y
e r L
o a
d
There is NO alarm shut-off button on the secondary gate operator.
Sensing Edges
To Primary MC-200 Edge 2 or Photo Cell Input
Matrix 1 Primary Operator
MATRIX 1
BACK-UP MODE
MADE in USA
LEAVE
OPEN
AUTOMATIC OPEN/CLOSE CONTROLS
ANTI
TAILGATE
EXIT
ON
OFF
CENTER
SAFETY
MIN
MAX
OFF
CLOSE TIMER
PARTIAL
ID
PLUG
POSITION
RECORDER
12VDC
GND
OBD PORT
BLACK BOX
24VDC
GND
RS-485 (+) to RS-485 (+)
RS-485 (-) to RS-485 (-)
RS-485 GND to RS-485 GND
11
To MC-200 EDGE 1 Input
Primary Operator
Matrix 1
BATTERY
PRIMARY
GATE
LEAVE
MAGLOCK
CLOSED
DELAY
OPEN
OPEN
MAG
OPEN
1 TIME
LEFT
RIGHT
OFF
1.5Sec
2Sec
LOCK
EXIT
CENTER
SAFETY
GATE
TAMPER
UL
ENTRAP
MOTOR MOTION
OPEN
OPEN
STOP
CLOSE
MAX
REVERSE SENSITIVITY
GATE SPEED
MOTOR OVERLOAD
GATE
MIN
NO LIMIT SWITCH /
STATUS
CLAMP SLIPPING
MAX
LIMIT
SWITCH
ON-LINE
MOTOR
ON-LINE
PRIMARY
SEC
GATE
GATE
SEC
GATE
Alarm Shut-OFF
MOTOR MOTION
STOP
OPEN
Matrix 1
STOP Button
UL 325 2016 Standard-MAX 1700FS Quick Install Rev 3
AC input
power
COM
NC
Tamper NO
COM
GND
Tamper IN
PHOTOCELL
EDGE 1
EDGE 2
ID PLUG
ERROR
UL ALARM 12V
ALARM RET
RESET
GND
OPEN
COM
CLOSE
BATTERY
IN USE
POWER
CLOSE

Advertisement