W O L F D U A L F U E L R A N G E S
P L A N N I N G I N F O R M A T I O N
Wolf dual fuel ranges come in 30" (762), 36"
(914), 48" (1219) and 60" (1524) widths.
Specifications on the following pages provide
overall dimensions, finished rough opening
dimensions and installation specifics for each
size of dual fuel range. We have minimized the
information contained in the illustrations,
concentrating on the critical information you
need to plan your installation.
H I G H A L T I T U D E
IMPORTANT NOTE: Caution must be used in
planning the proper installation of the Wolf dual
Wolf dual fuel
fuel range to avoid fires or damage to adjacent
ranges using natural
gas function up to an
cabinetry or kitchen equipment. Please follow
altitude of 8,000'
the minimum clearances established in the
(2438 m) without
finished rough opening dimensions. Refer to
any adjustment.
specifications on the following pages for your
Natural gas and LP
gas installations
model.
from 8,000' (2438 m)
It is recommended that you use a Wolf Pro
to 11,000' (3353 m)
need the high
ventilation hood or hood liner with the Wolf dual
altitude kit. Contact
fuel range. Refer to pages 102–114 for Pro
your Wolf dealer for
ventilation specifications.
details.
B U R N E R R A T I N G
Dual Fuel Ranges
Surface Burners
Infrared Charbroiler
Infrared Griddle
Natural Gas
LP Gas
Infrared Double Griddle
Natural Gas
LP Gas
Dimensions in
French Top
parentheses are in
millimeters unless
Refer to the specific model requirements
otherwise specified.
for risers in non-island installations.
66
15,000 Btu/hr (4.4 kW)
with 950 Btu/hr (.3 kW)
delivered at simmer
(1) 9,200 Btu/hr (2.7 kW)
with 325 Btu/hr (.1 kW)
delivered at simmer
16,000 Btu/hr (4.7 kW)
15,000 Btu/hr (4.4 kW)
13,000 Btu/hr (3.8 kW)
(2) 15,000 Btu/hr (4.4 kW)
(2) 13,000 Btu/hr (3.8 kW)
15,000 Btu/hr (4.4 kW)
E L E C T R I C A L | G A S R E Q U I R E M E N T S
Specifications on the following pages provide
electrical and gas requirements for each size
of dual fuel range.
Locate electrical and gas supply within the
shaded area shown in the Installation
Specifications illustration for your model.
Wolf dual fuel ranges are designed with a
terminal block on the rear of the range. The
terminal block allows for a 3-wire or 4-wire
installation. For a 4-wire installation, the ground
strap from the unit to the terminal block must be
cut. Two concentric knockouts on the base of
the unit are provided to allow a certified electri-
cal contractor to wire the range directly to the
electrical supply. The terminal block will also
accept an appliance cord that is sized correctly
for the voltage and amperage of your range.
Wolf dual fuel ranges are designed to operate on
natural gas at 5" (12.5 mb) WC (water column)
pressure or LP (propane) gas at 10" (25 mb) WC
pressure. The minimum line pressure for natural
gas is 7" (17.5 mb) WC and 11" (27.4 mb) WC
for LP gas. The maximum gas supply pressure to
the regulator should never exceed 14" (34.9 mb)
WC, .5 psi (3.5 kPa).
Wolf recommends the use of a
commercial-type flex hose; this is the minimum
size that may be used. All plumbing to the flex
3
hose must be
/
" (19) minimum I.D. pipe.
4
IMPORTANT NOTE: A separate external gas
shut-off valve must be located near the range
in an accessible location.
You must follow all National Electrical Code and
gas regulations. In addition, be aware of local
codes and ordinances when installing your
services.