V E N T I L A T I O N R E C O M M E N D A T I O N S
M I N I M U M C F M R E C O M M E N D A T I O N S F O R W O L F C O O K I N G P R O D U C T S
MODEL
Cooktops and Integrated Modules
CT15I, CT15E, CT15G, IG15*, IS15*, IF15* and IM15
CT30I, CT30IU, CT30E, CT30EU and CT30G
CT36I, CT36IU, CT36E, CT36EU and CT36G
Dual Fuel Ranges
DF304
DF366, DF364C and DF364G
DF486C, DF486G, DF484CG, DF484DG and DF484F
DF606DG, DF606F, DF606CG, DF604CF and DF604GF
Sealed Burner Rangetops
SRT304
SRT366
SRT364C and SRT364G
SRT486C, SRT486G, SRT484CG, SRT484DG and SRT484F
Gas Ranges
R304
R366, R364C and R364G
R488, R486C, R486G, R484CG, R484DG and R484F
R606DG, R606F and R606CG
Gas Rangetops
RT366, RT364C, RT364G and RT362F
RT488, RT486C, RT486G, RT484CG, RT484DG and RT484F
*Downdraft systems are not recommended for use with the electric grill, steamer and fryer modules.
C O O K T O P V E N T I L A T I O N B L O W E R O P T I O N S
INTERNAL BLOWERS
CFM
450
500
Cooktop Hoods
CTWH30
801643
CTWH36
IH4227
Downdraft Ventilation Systems
DD30I
Included
DD30R
DD36I
Included
DD36R
DD45I
Included
DD45R
IN-LINE BLOWERS
600
900
600
808331
801644
801645
808331
801644
801645
808331
COOKTOP HOODS
DOWNDRAFTS
CFM
CFM
215
150
450
350
600
500
500
500
REMOTE BLOWERS
1100
600
900
808332
801640
801641
808332
801640
801641
808332
801640
801641
808332
801641
808332
801641
808332
801641
CFM recommendations are based on
total Btu/hr output. Wolf recommends
1 CFM per 100 Btu/hr (.03 kW).
PRO HOODS
CFM
215
500
500
500
900
1100
1500
500
900
900
900
500
900
1100
1500
900
1100
1200
1500
801642
804701
801642
804701
801642
804701
801642
804701
801642
804701
801642
804701
115