E S E R I E S B U I L T - I N O V E N S
O V E R A L L D I M E N S I O N S
E Series Built-In Single Oven
1"
(25)
7
27
/
"
8
(708)
7
5
29
/
"
2
/
"
8
8
(759)
(67)
1
Unit dimensions may vary to ±
/
" (3).
8
I N S T A L L A T I O N S P E C I F I C A T I O N S
E Series Built-In Single Oven
Standard Installation—Wall Application
24"
min (610)
3
27
/
"
OPENING DEPTH
16
(691)
OPENING
HEIGHT
Standard Installation—Undercounter Application
3
3
/
"
4
min (95)
3
27
/
"
16
(691)
OPENING
HEIGHT
36"
(914)
24"
min (610)
STANDARD
OPENING DEPTH
FLOOR TO
COUNTER
HEIGHT
3
4
/
"
4
min (121)
RIGHT SIDE VIEW
TOP VIEW
CONDUIT
CHANNEL
1
27
/
"
16
(687)
28
7
1
/
"
8
(48)
3
23
/
"
4
(603)
BEHIND FRAME
OPEN OVEN DOOR
29
33"
(838)
RECOMMENDED CABINET WIDTH
30"
min (762)
1
28
/
"
2
(724)
OPENING WIDTH
ELECTRICAL LOCATION
WITHIN OPENING
(102)
APPLIES ONLY TO
CABINETS DEEPER
5"
THAN 24" (610)
(127)
33"
(838)
RECOMMENDED CABINET WIDTH
30"
min (762)
5"
ELECTRICAL
(127)
LOCATION WITHIN
OPENING APPLIES
(102)
ONLY TO CABINETS
DEEPER THAN 24" (610)
1
28
/
"
2
(724)
OPENING WIDTH
M O D E L O P T I O N S
E Series Built-In Single Oven
1
1
/
"
4
Framed
(32)
Unframed
7
1
/
"
8
(48)
3
23
/
"
4
S P E C I F I C A T I O N S
(603)
E Series Built-In Single Oven
1
/
"
4
(718)
Overall Width
Overall Height
Overall Depth
22"
(559)
Door Clearance
Overall Oven
Interior Capacity
Overall Interior Dim
7
/
"
8
(759)
(W x H x D)
Usable Interior Dim
(W x H x D)
Min Cabinet Width
Standard
Flush Inset
Min Cabinet Depth
Standard
Flush Inset
Min Base Support
E
Opening Width
Flush Inset Width
Opening Height
Flush Inset Height
Trim Overlaps
4"
E
E
Electrical Supply
E
Conduit
Electrical Rating
Total Amps
Shipping Weight
I N S T A L L A T I O N O P T I O N S
Wolf E Series built-in ovens may be used in a
standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry. Refer to the
following illustrations.
E
E
IMPORTANT NOTE: Unless you are using
4"
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset instal-
lation, it is recommended that the electrical
supply be placed in an adjacent cabinet within
reach of the conduit. Choose the location
shown in the illustrations that best suits your
installation.
SO30-2F/S
SO30-2U/S
7
29
/
" (759)
8
7
27
/
" (708)
8
3
23
/
" (603)
4
22" (559)
4.5 cu ft (127 L)
1
25" x 16
/
" x 19"
2
(635 x 419 x 483)
1
1
3
21
/
" x 16
/
" x 16
/
"
2
2
8
(546 x 419 x 416)
30" (762)
33" (838)
24" (610)
25" (635)
250 lbs (113 kg)
1
28
/
" (724)
2
3
30
/
" (772) min
8
3
27
/
" (691)
16
1
28
/
" (724) min
2
5
/
" (16) top
8
1
/
" (3) bottom
8
3
/
" (19) each side
4
240/208 V AC, 60 Hz
30 amp circuit
4' (1.2 m) flexible 3-wire
5.1 kW at 240 V
3.8 kW at 208 V
21
273 lbs (124 kg)