W O L F P R O V E N T I L A T I O N
B L O W E R C O N S I D E R A T I O N S
All Pro ventilation hoods and hood liners are
shipped without the blower assembly. Internal,
in-line and remote blower assemblies are avail-
able. Remote blowers can be mounted on the
roof or an exterior wall.
The blower assemblies are quite varied, and
depending on the amount of air you want to
move and the length of the duct run, you have
many options.
A straight, short duct run with a limited number
of elbows and transitions will allow the ventila-
tion hood to perform most efficiently. Pro
ventilation hoods and hood liners will operate
most efficiently when ductwork does not exceed
50' (15 m) in length.
D U C T I N G C O N S I D E R A T I O N S
Pro Low-Profile Wall Hoods
(Refer to the following page for additional ducting considerations.)
ROOF CAP OR REMOTE BLOWER
10"
(254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
10"
(254)
HEIGHT OF HOOD
22"
DEPTH OF HOOD
30"
36"
TO
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: 10" (254) ROUND ACCESSORY TRANSITION SHOWN IN VERTICAL DISCHARGE APPLICATION WITH
IN-LINE OR REMOTE BLOWER. REFER TO INSTALLATION INSTRUCTIONS FOR HORIZONTAL DISHCARGE.
A remote mounted blower will minimize the
amount of blower noise, but will not eliminate
the noise completely.
IMPORTANT NOTE: Install these ventilation
hoods and hood liners only with a Wolf blower.
Refer to the Pro ventilation recommendations on
pages 117–120.
DUCTWORK INSTALLATION
THROUGH ROOF
ACCESSORY TRANSITION
FOR IN-LINE OR
REMOTE BLOWER
3
1
17
/
"W x 4
/
"D TO 10" ROUND
4
4
3
9
/
"H (INCLUDING FLANGES)
8
VERTICAL DISCHARGE
WALL HOOD
(559)
Pro 24" (610) Deep Wall Hoods
ROOF CAP OR REMOTE BLOWER
10"
(254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
18"
(457)
HEIGHT OF HOOD
WALL HOOD
24"
DEPTH OF HOOD
30"
36"
TO
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
DUCTWORK INSTALLATION
THROUGH ROOF
TRANSITION
1
22
/
"W x 9"D TO 10" ROUND
4
10"H (INCLUDING FLANGES)
VERTICAL DISCHARGE
(610)
111