W O L F I N T E G R A T E D M O D U L E S
P L A N N I N G I N F O R M A T I O N
The illustrations provide the overall dimensions
and finished cut-out dimensions that you need
to plan for in your installation.
IMPORTANT NOTE: When multiple cooktops or
modules are installed side by side, refer to page
55 for countertop cut-out dimensions.
This cooktop can accommodate a Wolf cooktop
hood, downdraft system or Pro ventilation hood
or hood liner. When installing a ventilation hood,
refer to the specific requirements of the hood for
the minimum dimension to the countertop. Refer
to pages 92–114 for ventilation specifications.
E L E C T R I C A L | G A S R E Q U I R E M E N T S
The electric ignition system is a safe, convenient
and reliable way to provide ignition for the burner.
The Wolf gas multi-function cooktop requires a
separate 120 V AC, 60 Hz power supply.
I N S T A L L A T I O N S P E C I F I C A T I O N S
Gas Multi-Function Cooktop
13"
max
(330)
18"
(457)
1
1
2
/
"**
19
/
"
2
4
(489)
1
2
/
"
(64)
COOKTOP CUT-OUT
2
min
DEPTH
(64)
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
LOCATION OF GAS
SUPPLY MAY ALSO
EXTEND 5" ON FLOOR
FROM BACK WALL
5"
(127)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.
Countertop Cut-Out Dimensions
The service should have its own 15 amp circuit
breaker, and a grounded 3-prong receptacle
should be located within reach of the power
cord. Locate electrical and gas supply within
the shaded area shown in the illustration.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
The gas multi-function cooktop is designed to
operate on natural gas at 5" (12.5 mb) WC
pressure or LP gas at 10" (25 mb) WC pressure.
The maximum gas supply pressure to the
regulator should never exceed 14" (34.9 mb)
WC, .5 psi (3.5 kPa). It is supplied with a
NPT male gas connection at the right rear corner
of the module. The male connector exits the
unit straight down, and you are supplied with a
regulator with two female connectors.
33"
(838) RECOMMENDED
CABINET WIDTH
7"*
min (178)
14"
CUT-OUT TO
(356)
COMBUSTIBLE
COOKTOP CUT-OUT
MATERIALS
WIDTH
(BOTH SIDES)
5"
(127)
E
G
15"
(381)
15"
(381)
LOCATION OF GAS SUPPLY
MAY ALSO EXTEND 5" ON
FLOOR FROM BACK WALL
15"
(381)
14"
(356)
COOKTOP CUT-OUT
WIDTH
1
19
/
"
4
(489)
COOKTOP
1
2
/
"
2
min
CUT-OUT DEPTH
(64)
FRONT OF COUNTERTOP
M O D E L O P T I O N S
Gas Multi-Function Cooktop
Classic / Natural Gas IM15/S
Classic / LP Gas
S P E C I F I C A T I O N S
Gas Multi-Function Cooktop
Overall Width
Overall Height
30"
(762)
COUNTERTOP TO
Overall Depth
COMBUSTIBLE
MATERIALS
Burner Rating
ABOVE COOKTOP
Cabinet Depth
Height Clearance*
Cut-Out Width
Cut-Out Depth
Electrical Supply
Power Cord
Gas Rating
Shipping Weight
*A minimum height clearance of 5
is required between countertop and any
combustible surface directly below the cooktop.
Unit dimensions may vary to ±
H I G H A L T I T U D E
The Wolf gas multi-
function cooktop
functions up to 8,000'
(2438 m) in altitude
without any adjust-
1
/
"
2
ment. If installation
is above 8,000'
(2438 m), contact
your Wolf dealer.
IM15/S-LP
15" (381)
5" (127)
21" (533)
18,000 Btu/hr
(5.1 kW)
3
22
/
" (578) min
4
5" (127) min
14" (356)
1
19
/
" (489)
4
120 V AC, 60 Hz
15 amp circuit
6' (1.8 m) 3-prong
18,000 Btu/hr
(5.1 kW)
30 lbs (14 kg)
1
/
" (140)
2
1
/
" (3).
8
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
63