E S E R I E S B U I L T - I N O V E N S
P L A N N I N G I N F O R M A T I O N
Wolf E Series built-in ovens are available as a
30" (762) wide single oven or 30" (762) double
oven in framed or unframed door styles.
For ease of installation, Wolf recommends using
33" (838) wide cabinets with the E Series ovens.
The cabinet base platform must be able to
support 250 lbs (113 kg) for a single oven and
400 lbs (181 kg) for a double oven.
For standard installations, the oven is installed
W O L F
W A R R A N T Y
by inserting into cabinetry from the front. The
oven has a face trim on all four sides and will
Wolf products are
overlap stiles and rails. The trim overlaps
covered by a two
(16) on the top,
and five year
(19) on each side.
residential warranty
(exclusions apply).
The flush inset installation requires the oven to
See warranty
be recessed into the cabinet. A minimum 33"
details at the end
(838) wide and 25" (635) deep cabinet is needed
of this guide.
if you want the front of the oven to be flush
with surrounding cabinetry.
Specifications on the following pages provide
overall dimensions, rough openings and installa-
tion specifics for E Series built-in ovens.
A Wolf E Series single oven may be installed
below an induction, electric or gas cooktop.
Wolf built-in ovens are designed and agency
approved for installation with Wolf cooktops
only. Refer to the electric and gas cooktops
sections for additional specifications.
M O D E L O P T I O N S
E Series Built-In Ovens
Single Oven
Framed
Unframed
Double Oven
Framed
Unframed
Dimensions in
parentheses are in
millimeters unless
otherwise specified.
10
5
/
8
1
3
/
" (3) on the bottom and
8
SO30-2F/S
SO30-2U/S
DO30-2F/S
DO30-2U/S
E L E C T R I C A L R E Q U I R E M E N T S
E Series single ovens require a separate,
grounded 3-wire 240/208 V AC, 60 Hz, 30 amp
service with its own circuit breaker. Double
ovens require a separate, grounded 3-wire
240/208 V AC, 60 Hz, 50 amp service with its
own circuit breaker.
IMPORTANT NOTE: Unless you are using
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset installa-
tion, it is recommended that the electrical supply
be placed in an adjacent cabinet within reach of
the conduit. A 2" (51) diameter hole to route the
"
conduit through cabinetry will be required. Refer
/
"
4
to the Installation Specifications illustrations on
the following pages for location of the electrical
supply.
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
This appliance must be installed in accordance with
National Electrical Code regulations as well as all
state, municipal and local codes. The correct
voltage, frequency and amperage must be supplied
to the appliance from a dedicated, grounded circuit
that is protected by a properly sized circuit breaker
or time delay fuse. The proper voltage, frequency
and amperage ratings are listed on the product
rating plate.
A C C E S S O R I E S
E Series Built-In Ovens
Bake stone accessory, includes
stone, rack and peel
Additional oven racks
Two-piece broiler pan and
temperature probe
Dehydration racks with door
stop
Accessories are available through
your Wolf dealer. To obtain local
dealer information, visit the
Showroom Locator section of our
website, wolfappliance.com.

Advertisement

Table of Contents
loading

Table of Contents