Wolf IG15/S User Manual page 13

L series ovens
Hide thumbs Also See for IG15/S:
Table of Contents

Advertisement

E S E R I E S B U I L T - I N O V E N S
O V E R A L L D I M E N S I O N S
E Series Built-In Double Oven
1"
(25)
3
50
/
"
8
(1280)
5
7
2
/
"
29
/
"
8
8
(67)
(759)
1
Unit dimensions may vary to ±
/
" (3).
8
I N S T A L L A T I O N S P E C I F I C A T I O N S
E Series Built-In Double Oven
Standard Installation
24"
min (610)
5
49
/
"
8
OPENING DEPTH
(1260)
OPENING
HEIGHT
67"
typical
(1702)
Refer to installation
instructions shipped
with each Wolf
product for detailed
specifications.
RIGHT SIDE VIEW
TOP VIEW
CONDUIT
CHANNEL
1
49
/
"
2
(1257)
28
7
1
/
"
8
(48)
OPEN OVEN DOOR
29
3
23
/
"
4
(603)
BEHIND FRAME
33"
(838)
RECOMMENDED CABINET WIDTH
30"
min (762)
1
28
/
"
2
(724)
OPENING WIDTH
ELECTRICAL LOCATION
WITHIN OPENING
(102)
APPLIES ONLY TO
CABINETS DEEPER
5"
THAN 24" (610)
(127)
M O D E L O P T I O N S
E Series Built-In Double Oven
1
1
/
"
4
Framed
(32)
Unframed
7
1
/
"
8
(48)
3
23
/
"
4
S P E C I F I C A T I O N S
(603)
E Series Built-In Double Oven
1
/
"
4
(718)
Overall Width
Overall Height
Overall Depth
22"
(559)
Door Clearance
Overall Oven Interior
Capacity (per oven)
Overall Interior Dim
7
/
"
8
(759)
(W x H x D)
Usable Interior Dim
(W x H x D)
Min Cabinet Width
Standard
Flush Inset
Min Cabinet Depth
Standard
Flush Inset
Min Base Support
Opening Width
Flush Inset Width
Opening Height
E
Flush Inset Height
Trim Overlaps
Electrical Supply
Conduit
Electrical Rating
Total Amps
Shipping Weight
4"
E
E
I N S T A L L A T I O N O P T I O N S
E
Wolf E Series built-in ovens may be used in a
standard installation, where the face trim
overlaps stiles and rails, or in a flush inset
installation with the front of the oven flush
with surrounding cabinetry. Refer to the
following illustrations.
IMPORTANT NOTE: Unless you are using
cabinets deeper than 24" (610) for a standard
installation or 25" (635) for a flush inset instal-
lation, it is recommended that the electrical
supply be placed in an adjacent cabinet within
reach of the conduit. Choose the location
shown in the illustration that best suits your
installation.
DO30-2F/S
DO30-2U/S
7
29
/
" (759)
8
3
50
/
" (1280)
8
3
23
/
" (603)
4
22" (559)
4.5 cu ft (127 L)
1
25" x 16
/
" x 19"
2
(635 x 419 x 483) each
1
1
3
21
/
" x 16
/
" x 16
/
"
2
2
8
(546 x 419 x 416) each
30" (762)
33" (838)
24" (610)
25" (635)
400 lbs (181 kg)
1
28
/
" (724)
2
3
30
/
" (772) min
8
5
49
/
" (1260)
8
15
50
/
" (1294) min
16
5
/
" (16) top
8
1
/
" (3) bottom
8
3
/
" (19) each side
4
240/208 V AC, 60 Hz
50 amp circuit
5' (1.5 m) flexible 3-wire
8.9 kW at 240 V
6.7 kW at 208 V
37
466 lbs (211 kg)
13

Advertisement

Table of Contents
loading

Table of Contents