W O L F P R O V E N T I L A T I O N
D U C T I N G C O N S I D E R A T I O N S
IMPORTANT NOTE: Unless a recirculating kit is
being used, all Wolf Pro ventilation hoods and
hood liners must be vented to the outside. Use
only metal ductwork.
Wolf Pro low-profile wall hoods come standard
from the factory with horizontal or vertical
discharge.
IMPORTANT NOTE: When using an in-line or
external blower with the low-profile hood, use
either the optional accessory 10" (254) round
transition or a custom piece. The rectangular
cut-out on the hood is 3
IMPORTANT NOTE: Internal blower WBLOWER-
50INT comes with a transition for use with
1
3
/
" (83) x 10" (254) ducting attached to the
4
blower. A 3
round transition is available as a sales accessory.
D U C T I N G C O N S I D E R A T I O N S
Pro 27" (686) Deep Wall Hoods
ROOF CAP OR REMOTE BLOWER
10"
(254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
18"
(457)
WALL HOOD
HEIGHT OF HOOD
27"
(686)
DEPTH OF HOOD
30"
36"
TO
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.
112
1
/
" (83) x 14" (356).
4
1
/
" (83) x 10" (254) to 8" (203)
4
DUCTWORK INSTALLATION
THROUGH ROOF
TRANSITION
1
22
/
"W x 9"D TO 10" ROUND
4
10"H (INCLUDING FLANGES)
VERTICAL DISCHARGE
Wolf Pro 24" (610) and 27" (686) deep wall
hoods have a vertical discharge. A horizontal
discharge kit is available as a sales accessory.
In a horizontal discharge application, additional
framework may be needed to accommodate the
remote blower. Consult your local HVAC
professional for specific requirements in this
application.
Wolf Pro wall chimney hoods, island hoods and
hood liners have a vertical discharge.
Refer to illustrations on the previous page for
ducting considerations for the Pro low-profile
and Pro 24" (610) deep wall hoods. Refer to
illustrations below for the Pro 27" (686) deep
wall hoods and Pro wall chimney hoods. Refer
to illustrations on the following page for the Pro
island hoods and Pro hood liners.
Pro Wall Chimney Hoods
ROOF CAP OR REMOTE BLOWER
10"
(254) ROUND DUCT
SOFFIT OR CABINET
OR DUCT COVER
18"
(457)
HEIGHT
WALL HOOD
OF HOOD
24"
DEPTH OF HOOD
30"
36"
TO
(762–914)
COUNTERTOP
TO BOTTOM OF
VENTILATION HOOD
36"
(914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
NOTE: VERTICAL DISCHARGE ONLY FOR PRO WALL CHIMNEY HOODS.
DUCTWORK INSTALLATION
THROUGH ROOF
TRANSITION
3
14"W x 9
/
"D TO 10" ROUND
4
7"H (INCLUDING FLANGES)
VERTICAL DISCHARGE
3
16
/
"
4
(425)
TOP OF WOOD
MOUNTING STRIP
(610)