17. Technical data

Tab. 17-1 - Specifications
Specifications
Air humidification output*
Transducer
Power supply
Power consumption
Fuse rating
Fan performance **
*
The humidifying performance depends on the length and the cross-section of the pipes/hoses
leading to the place of humidification. See Chapter 10: Aerosol distribution systems
**
The fan performance depends on the length of the pipes/tubes, the way they were installed
and their diameters. The double fan only increases compression, not the volume of the air.
See Chapter 10: Aerosol distribution systems
Tab. 17-2 - Safety devices
Safety devices
Dry-running protection with
functional redundancy
Overheating protection
Overflow protection
Disconnect protection
Monitoring
Tab. 17-3 - Operation conditions
Operation conditions
Maximum air humidity
Air temperature
Demineralised water pressure
Demineralised water quality
Demineralised water
conductivity
[MBA_UB-1...4-CT_3.1_EN] Rev.: 02/2022 Translation of the original instructions
No liability accepted for translation or printing errors. Subject to changes in dimensions, weights and other technical data.
All rights reserved. Modifications, reprints and photomechanical reproduction, even in extract from, require the express perm ission of BOGA GmbH, Werkstraße 16, D-59494 Soest.
UB-1/CT/3.1
kg/h
0.5
Unit
1
V / 50 Hz
230
VA / 50 Hz
100
A
2.5 T
m³/h
120
Description
If the water level falls below the minimum level in the fluid tank, the
humidification switches off. For this purpose, both level switches are
monitored separately.
The humidifier stops humidifying at water temperatures > 60 °C.
If the humidifier fluid tank is overfilled, the excess water is drained off
to the outside through the overflow.
There are no defects in the event of electrical interruptions
between the oscillator board and the transducer.
Monitoring of important system components with integrated
problem solver routines.
Parameter
< 90 % relative humidity – no condensation!
5 - 45 °C
1 - 4 bar
fully demineralised
5 - 20 µS/cm
UB-2/CT/3.1 UB-3/CT/3.1 UB-4/CT/3.1
1.0
1.5
2
3
230
230
130
160
2.5 T
2.5 T
120
120
2.0
4
230
190
2.5 T
120