Device Overview - Boga AIRWIN UB-1 4/CT/3.1 Series Installation And Operating Instructions Manual

Ultrasonic universal humidifier
Table of Contents

Advertisement

7. Device overview

Green indicator light
Lights up when
the humidifier is
switched on
Axial fan
max. 120 m³/h
ON/OFF switch,
Fuse 2.5 A T
and device connection
[MBA_UB-1...4-CT_3.1_EN] Rev.: 02/2022 Translation of the original instructions
No liability accepted for translation or printing errors. Subject to changes in dimensions, weights and other technical data.
All rights reserved. Modifications, reprints and photomechanical reproduction, even in extract from, require the express perm ission of BOGA GmbH, Werkstraße 16, D-59494 Soest.
Fig. 3 - UB-4/CT/3.1 Overview
Aerosol outlet pipes
Ø 40 mm
Water overflow
Push-in connection Ø 12 mm
Water filter
Screwed connection for Ø 6/4 mm
Stop cock
for Ø 6 mm
Outlet to the on-site drainage
Push-in connection Ø 12 mm
Water drainage
Push-in connection Ø 12 mm
Demineralised water inlet
1 bar < pressure ≤ 4 bar
5 µS/cm < conductivity ≤ 20 µS/cm
Interface
control signals
15-poles