Fig. 28 - Decoding LED-Display

13.8 Resetting the maintenance interval

The resetting of the LED display may only be carried out by trained specialists.
After service or maintenance has been carried out, the LED display can be reset as follows:
1. Switch off the device and let it drain.
2. Remove the housing cover.
3. Deactivate the safety chain by removing the plug 15 poles.
4. Switch on the device, wait for the rinsing cycle and the
AquaDrain Duration.
5. Do the following action 5 times in a row. Raise level switch
S2 to the upper level, wait 1 second and then move it back
to the lower level.
6. If the reset of the maintenance interval successful, the LED
has gone out.
7. If the LED does not go out, repeat the process.
8. Put the housing cover back on and activate the safety
chain.