GARANT Ready-to-go workbench
de
4. Push the lever up.
»
Workbench is on its feet.
7.
Storage
bg
Storage temperature between -10°C and +60°C.
Store in an enclosed dry room.
da
Atmospheric humidity: 90 %, non-condensing.
8.
Maintenance
en
8.1.
QUALIFICATIONS OF PERSONNEL
See Personnel qualifications
8.2.
SPARE PARTS
fi
Order original spare parts from the Hoffmann Group Customer Service.
8.3.
MAINTENANCE
fr
Do not use alcoholic, abrasive or solvent-based cleaning agents.
Interval
Before each occasion of use
it
Monthly
hr
If the workbench is dirty
lt
nl
In the event of damage to
the workbench, components
and accessories
no
9.
Technical data
Dimensions and weights
pl
Article no.
920801 – 921137
pt
921141 – 921217
923621 – 923757
ro
924011 – 924094
*Load capacity of undercarriage is max. 400 kg in total
sv
Load capacities
Item
sk
Drawer
Storage shelf
sl
Temperatures
Working environment
Storage and transport
es
cs
hu
20
Maintenance work
Check workbench for external damage.
Check all components and screw fastenings on the work-
bench for tightness and operation.
Remove external dust and dirt.
Check for damage and cracks.
Clean the side panels, metal fronts, drawers and feet with
paint cleaner.
Clean the worktop with a damp cloth.
Block access to the workbench and prevent its use.
Have damaged components and accessories replaced im-
mediately.
Weight
119 kg - 189 kg
155 kg – 223 kg
111 kg - 173 kg
97 kg – 150 kg
Load capacity
800 kg
800 kg
400 kg
(lowered)*
400 kg
Load capacity
75 kg
20 kg
0 °C to +40 °C
-10 °C to +60 °C
Performed by
Trained person
Trained person
Trained person
Trained specialist for mechan-
ical work