Summary Of Warnings - Goodwe ET Series User Manual

Hybrid inverter
Hide thumbs Also See for ET Series:
Table of Contents

Advertisement

Max. altitude for operation (m)
Cooling
Noise level (dB)
Control
Communication with the BMS
Communication with the Smart
Meter
Communication with EMS
Communication with the Portal
Weight (kg)
Dimensions (Width*Height*Depth
mm)
Mounting
Degree of protection
Consumption in Stand-by mode
(W) ****
Topology
Certificates and standards
Grid regulation
Safety regulation
EMC
* For 1000V system, max rated voltage is 950V
** According to local regulations
*** It will only reach if there is enough energy from PV and from the battery
**** without Back-Up output
ET SERIES INVERTER CERTIFICATES
MORE TESTS
For Australian requirements, in the THDi test, Zref must be added between the inverter and the mains.
RA, XA for phase conductor.
RN, XN for a neutral wire
Ref:
RA=0.24;XA=j0;15 at 50Hz;
RN=0.16;XN=j0.10 at 50Hz;

4.4 SUMMARY OF WARNINGS

[1] The inverter cannot be installed near flammable and explosive substances or strong electromagnetic fields
[2] Remember this inverter is heavy! Be careful when removing from packaging
[3] You must not reverse the polarity of the PV string, otherwise, the inverter could be damaged
[4] Before connecting the inverter, make sure the battery switch is off and the battery voltage rating meets the ET specification, before
connecting the battery to the inverter, make sure the inverter is completely disconnected from the PV and AC power
[5] Make sure the inverter is completely disconnected from DC or AC power before connecting the AC cable
[6] Make sure the AC cable is completely disconnected from the AC power supply before connecting the Smart Meter and CT
DEFINITION OF PROTECTION CATEGORY
Definition of overvoltage category
CATEGORY I
For specially protected devices, which are low-current appliances
CATEGORY II
On outlets from sub-distributors, which is a device intended for connection to a fixed installation
CATEGORY III
Behind the main switchboard, which is a fixed installation device
CATEGORY IV
At the entrance to the building, when it is the beginning of the installation
24
AS/NZS 4777.2:2015
IEC62109-1&2, IEC62040-1
EN61000-6-1, EN61000-6-2, EN61000-6-3,
EN61000-6-4, EN61000A-4-16A, EN61000-4-18, EN61000-4-29
 4000
Passive cooling
<30
LED and app
RS485; CAN
RS485
VRS485 (Isolated)
Wi-FI
25
516*415*180
Wall holder
IP65
<15
Without a transformer
CEI 0-21; VDE4105-AR-N; VDE0126-
1-1; EN50438; G83/2; G100
IEC62109-1&2, IEC62040-1
24