Ametek LAND IQ Series User Manual page 45

Table of Contents

Advertisement

Fixed Spot Thermometer
CMD
Function
READ
response
PPD
Ppick
0012
decay
rate
PPM
Ppick
0000
mode
PPT
500
Ppick
threshold
REF
Refresh
0000
TFN
0001
Time
function
TMP
Temper-
973
ature
HTP
15568
Temper-
ature in
16T
UDR
0000
Under-
range
BTP
Bobbin
55
temp
TLV
IRT min
500
temp
THV
IRT max
1700
temp
User Guide
SET
Range
example
SAPD 1
0-15
SAPPM
0, 1
1
SAPPT
IRTmin-max 1°
1000
SAREF 1 0, 1
SATFN 2 0-3
N/A
(IRTmin1)
> (max+1)
N/A
(IRTmin-1)
> (max+1)
N/A
0, 1
N/A
-
N/A
IRTmin
N/A
IRTmax
Resolution Default
1
0012
-
0
IRTmin
-
0
1
0
-
1/16°
-
-
-
16T
-
-
IRTmin
-
IRTmax
series
Comments
Interval
0000 0°/s
0001 250m°/s
0002 500m°/s
0003 1°/s
0004 2°/s
0005 4°/s
0006 8°/s
0007 16°/s
0008 32°/s
0009 64°/s
0010 128°/s
0011 256°/s
0012 512°/s
0013
-
0014
-
0015
-
0 = reset
1 = hold
0 = refreshON
1 = refreshOFF
Refresh cal/config
EEPROM to RAM every
task cycle. NOTE:
changing a config
parameter switches
refresh off and MEM
flag to 1. NOTE:
Switching refresh to
ON sets MEM flag to
0.
i.e. RAM=EEPROM
0000 = no time
function selected
0001 = Averager
0002 = Peak picker
0003 = Track & hold
0 = in range
1 = under-range
Ratio bobbin temp °C
IRT range fixed
IRT range fixed
A - 7

Advertisement

Table of Contents
loading

Table of Contents