Fixed Spot Thermometer
User Accessible Commands (continued)
The use of text-based flags is designed specifically for use with a Windows-
based configuration tool. The flags are also compatible with terminal programs.
This is used to transfer the data directly into sequential files, under Windows,
for subsequent manipulation. This simple protocol is very flexible and
expandable.
For example:
RAIFO 0 Processor Identification report - text strings<x chars
[start]
Processor Information
Processor identifier
Application code version
Hardware identifier
[end]
RAIFO 1 Current thermometer Details report - formatted strings NN⊗ : SN x r y or SNzt xxxx
NN = index 00-10
r = 0 - 9
[start]
[Thermometer Information]
Index: Type
Thermometer Units of operation
Thermometer Temperature Maximum
Thermometer Temperature Minimum
Laser present
[end]
RAIFO 2 Configuration report - text strings CMD NNNN
[start]
[Configuration information]
Label
Thermometer
Emissivity
Nongreyness
Timefunction
Averager constant
PeakPick Mode
PeakPick threshold
Peakpick OnDelay
Peakpick OffDelay
Peakpick Decay constant
Alarm 1 Level
Alarm 1 Mode
Alarm 1Contact mode
Alarm 2 Level
Alarm 2 Mode
Alarm 2 Contact mode
Output max
Outputmin
Output mode
[end]
RAIFO 3 Contact report - text strings <x chars
[start]
[Contact information]
Land
Address
Tel
[end]
User Guide
SN = SoloNet
y = laser or ZTxxxx Specials No.
[start]
[Processor Information]
Solonet
Appl Code: V 1.00 or Zxxxx
Hardware ID : 0xF0
[end]
x = wavelength ⊗ = space
[start]
[Thermometer Information]
xx
00 : LN1
01 : SN1
02 : SN2
03 : SN5
04 : SNR1
IRU
xxxx
THV
xxxx
TLV
xxxx
LPF
xxxx
[end]
[start]
[Configuration information]
LBL SOLOnet
X
IRT
0001
EMS 1000
NGR 1000
TFN
0000
AVR 0001
PPM 0000
PPT
0500
PON 0000
POF 0010
PPD 0012
A1L
1700
A1M 0001
AC1 0001
A2L
1700
A2M 0001
AC2 0001
OMX 1700
OMN 0500
OPT 0000
[end]
[start]
[Contact information]
AMETEK Land Instruments International
Dronfield S18 1DJ, UK
Tel: +44 (0)1246 417691
[end]