Ametek LAND SYSTEM 4 User Supplement

Target orbiting thermometer
Hide thumbs Also See for LAND SYSTEM 4:

Advertisement

Quick Links

System 4
Target Orbiting Thermometer
User Supplement
Issue 5
28 March 2014
Publication Nº 198.069
Language: English
© Land Instruments International, 2008-2014

Advertisement

loading

Summary of Contents for Ametek LAND SYSTEM 4

  • Page 1 System 4 Target Orbiting Thermometer User Supplement Issue 5 28 March 2014 Publication Nº 198.069 Language: English © Land Instruments International, 2008-2014...
  • Page 2 IMPORTANT INFORMATION - PLEASE READ Health and Safety Information Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS - before using this product. If there is any instruction which you do not understand. DO NOT USE THE PRODUCT. Safety Signs WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or...
  • Page 3 This instrument complies with current European directives relating to Electromagnetic Compatibility 89/336/EEC and Low Voltage Directive 73/23/EEC. The Quality Management System of Ametek Motors (Shanghai) Co. Limited is approved to ISO9001:2008 for the Design and Manufacturing of Motors and the Manufacturing of Gas Analysers.
  • Page 4 Target Orbiting Thermometer User Supplement...
  • Page 5: Table Of Contents

    User Supplement Target Orbiting Thermometer Contents About this Supplement System 4 Target Orbiting Thermometers Supplementary Specification Principle of Operation Suggested settings for use in 'Peak Picker' mode...
  • Page 6 Target Orbiting Thermometer User Supplement Accuracy Accuracy for a ‘standard‘ System 4 M1 Thermometer = ±0.4%K Accuracy for a ‘Target Orbiter’ System 4 M1 Thermometer = ±0.8%K Accuracy for a ‘standard‘ System 4 M2 Thermometer = ±0.25%K + 1K Accuracy for a ‘Target Orbiter’ System 4 M1 Thermometer = ±0.5%K + 1K Specification ±°C Temperature °C...
  • Page 7: About This Supplement

    User Supplement Target Orbiting Thermometer About this Supplement This supplement is gives the information necessary to understand the principle of operation of the Target Orbiting (TO) option fitted to your System 4 Thermometer. This supplement must be used in conjunction with the System 4 Thermometer User Guide, supplied as standard with all System 4 Thermometers.
  • Page 8 Target Orbiting Thermometer User Supplement d = target spot diameter ≤ D/100 (D/200 for high temperature versions) Optical Field of View (=D/d) Fig. 1 Field of view of Standard System 4 Thermometer S4980253 d = target spot diameter (identical to a 'standard' thermometer) rad = D/29 Optical Field of View (=D/d) Fig.
  • Page 9: Principle Of Operation

    User Supplement Target Orbiting Thermometer Principle of Operation Fig. 1 shows the field of view for a standard System 4 Thermometer. The axis of the field of view is fixed at the centre of the thermometer lens and is at right angles to the front face of the thermometer.
  • Page 10: Suggested Settings For Use In 'Peak Picker' Mode

    Target Orbiting Thermometer User Supplement 3.1 Suggested settings for use in 'Peak Picker' mode Use the Landmark Graphic processor in Reset mode, to ensure that the indication falls to zero when no hot material is within the target orbit. The Threshold level for the Peak Picker is the temperature above which the Peak Picker is active.
  • Page 11 PRODUCT WARRANTY Thank you for purchasing your new product from Land Instruments International. This Land manufacturer’s ‘back-to-base’ warranty covers product malfunctions arising from defects in design or manufacture. The warranty period commences on the instrument despatch date from the Land Instruments International Ltd.
  • Page 12 • Tel: +44 (0) 1246 417691 • Fax: +44 (0) 1246 410585 Email: land.infrared@ametek.co.uk • www.landinst.com A M E T E K L a n d , I n c . • 1 5 0 F r e e p o r t R d .