5.3 Auto reset

This function allows the pump to automatically check
if the operating conditions are back to normal. If the
operating conditions are back to normal, the alarm
indication will be reset automatically.
Alarm
Auto-reset action
The pump will attempt eight restarts at five-minute
intervals. If not successful, this cycle will be repeated
after 24 hours.
In twin configuration Duty/Assist, there is no reset if
Dry running
only one pump is in dry run alarm. If both pumps are in
dry run, the reset will be staggered.
In twin configuration Duty/Standby, the pump will
attempt to restart immediately independent of the
second pump.
This function will attempt to reset after 12 hours, and
Anti-cycling
the pump will return to normal operation.
Max. runtime
None
The factory setting is on.
The auto-reset function works as follows:
Configurable
Yes
Yes
Fixed disabled
Default
On
Off