Empty pans or those with a thin base
Do not heat empty pans, nor use pans with a thin base.
The hob is equipped with an internal safety system.
However, an empty pan may heat up so quickly that the
"automatic switch off" function may not have time to
react and the pan may reach very high temperatures.
The base of the pan could melt and damage the glass
on the hob. In this case, do not touch the pan and
switch the hotplate off. If it fails to work after it has
cooled down, please contact the Technical Assistance
Service.
Pan detection
Each hotplate has a lower limit for pan detection. This
depends on the diameter of the ferromagnetic area of
the cookware and the material from which its base is
made. For this reason, you should always use the
hotplate that best matches the diameter of the base of
the pan.

Installation and connection

5Installation and connection
D o not install the appliance behind a decorative door
I n s t a l l a t i o n a n d c o n n e c t i o n
or the door of a kitchen unit, as this may cause the
appliance to overheat.

Electrical connection

Only licensed specialists may connect the appliance.It
is important that you comply with the requirements of
your electricity supplier.
Any damage arising from the appliance being
connected incorrectly will invalidate the warranty.
Caution!
Your appliance comes with the enclosed cable for
permanently connecting it to the mains electricity
supply.
Except in the event of damage, never remove the cable
from the appliance or replace it with another cable (with
or without plug).
Caution!
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
:
Warning – Danger of death!
There is a risk of electric shock if you touch live
components.
Always make sure your hands are dry when you
touch or hold the mains plug.
Only pull out the mains cable by taking hold of the
plug and removing the plug; never pull it out by the
mains cable itself, as this could damage it.
Never unplug the mains plug when the appliance is
in operation.
Please note the following information and ensure that:
Notes
The mains plug fits the socket.
The cable cross section is adequate.
The earthing system is properly installed.
The mains cable is only replaced by a qualified
electrician (if this is necessary).Spare mains cables
can be ordered from our after-sales service.
No power strips/multi-way connectors or extension
cables are used.
If using a residual current device, only use one that
bears the mark
.
z
The presence of this mark is the only way to be sure
that it fulfils all the applicable regulations.
The mains plug can be accessed at all times.
The mains cable is not kinked, crushed, modified or
severed.
The mains cable does not come into contact with
heat sources.
For the installer
An all-pole isolating switch with a contact gap of at
least 3 mm must be present in the installation circuit.
This is not necessary if the appliance is connected
by a plug that is accessible to the user.