Icmp(-X) Configuration Via Communicator - Barco DP K-19B Series User And Installation Manual

Table of Contents

Advertisement

ICMP(-X)

7.10 ICMP(-X) configuration via Communicator

About ICMP(-X) configuration
Following parameters are available to configure the ICMP(-X):
Global settings: allows defining name of the ICMP(-X), host name (network identifier) and IP address
which can be used for communication with external content devices.
User settings: definition of all users allowed on the ICMP(-X).
Server settings: definition of access to servers and storage libraries of content (movies, KDM, etc.).
Player settings: Audio delay and audio output frequency.
Audio channel: allows defining the mapping of audio channels (content) on each audio output (AES
outputs of the ICMP).
Scheduler setting: Enable/Disable scheduler at startup, delays allowed in scheduler mode and length of
schedule history.
Devices: allows defining communication ports settings, to access external devices controlled by the
automation.
Automation Cues: event cues that are triggered from different sources and to which can be assigned
actions to be executed by the automation engine.
Verify internal clock of the ICMP(-X).
All installation and maintenance operations on the ICMP(-X) are performed via Communicator, the
Barco configuration software. Please refer to the Communicator user guide for further information.
About Default settings
The restore of factory setting is a feature that allows removing all settings performed on the ICMP (-X) and
replaces them with the default values set at the factory. Please refer to the Communicator user guide for
further information.
About the ICMP(-X) internal clock
The crystal on the ICMP (-X) board that manages the clock shows a certain drift (all crystals do). With the
Communicator the internal clock can be adjusted. This maintenance action should be repeated every 3
months. When neglected the system will locks up.
From ICMP (-X) software version 1.2.1 onwards it is possible to enable NTP (Network Time Protocol). You
have to configure (at installation) an IP address where the ICMP can find a sync signal. From then on, and as
long as the connection is active, the ICMP will automatically keep its clock correct. For detailed instructions
see user guide of the Communicator.
About test patterns
Often, during ICMP (-X) settings, it could be necessary to resize displayed image. In most of the cases, to
achieve this, test patterns are displayed on screen. However, some test patterns are provided on the fly by the
projector and can not be resized.
List of test patterns that can be resized:
2K Barco Enabling Bright Outcomes
BARCO_rgb_primarylogo_red_2K
Convergence_pattern
Convergence_pattern_green_on_blue
Convergence_pattern_red_on_blue
Convergence_pattern_xxB
Convergence_pattern_xxC
Convergence_pattern_xxS
DualStack3D_Left
DualStack3D_Right
Focus
FocusGreen
FocusWhite
112
R5905753 /17
DPxK-19B/23B/P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents