ELECTRICAL CHARACTERISTICS

These models are available for either 200 -
220, or 230 - 240 applied voltage, 50 and
60Hz, 1 and 3 phase electrical connection.
Be sure to check the wiring diagram located
inside the front panel. It shows electrical cir-
cuits and connections. See Access For
Hook-Up under ELECTRICAL HOOK-UP.
• All electrical work must conform with the
requirements of national, state and local
electrical codes.
• When installing or servicing the unit,
always check the data plate located
toward the rear of the counter top to
make certain proper parts are used and
the correct service rendered. DO NOT
apply a voltage to any unit other than
that shown on the data plate. If in doubt,
consult your local power company.

ELECTRICAL CONNECTIONS

• A remote circuit breaker or fuse should
be installed in main power supply
located in a path of exit and clearly iden-
tified.
• When installed, the unit must be electri-
cally grounded in accordance with local
codes, or in the absence of local codes,
with the National Electrical Code, ANSI/
NFPA 70, or for Canada, the Canadian
Electrical Code, CSA C22.2, as applica-
ble.
• Use copper wire only for connections.
• If power run is over 50 feet, use next
larger size wire.
3 - 18E INSTALLATION
3-1
broaster.com Manual #17268 9/20 rev 9/20
18E Suggested Wiring Capacity Table:
Phase
Volts
1
208
1
220
1
230
1
240
3
208
3
240
3
220/380
3
230/400
3
240/415
Breaker
Amps
Wire
or Fuse
48
#8
60
50
#8
60
43
#8
60
45
#8
60
28
#8
40
26
#8
40
16.8
#10
20
14.3
#10
20
15
#10
20