6EDL_SPI_LINK configuration dongle for 6EDL71x1 series
User guide

Instructions

5
Instructions
1. Install the
Infineon Developer Center
2. After installing the launcher, select the Manage Tools tab and locate the MOTIX™ BPA Motor Control
Workbench to install on the PC.
Figure 12
Download OTIX™ BPA Motor Control Workbench
3. Click the Start button to run the application.
Note:
It is recommended to check regularly for updates and install the updates when they are available.
Figure 13
MOTIX™ BPA Motor Control Workbench
4. Connect the 6EDL_SPI_LINK adapter to the PC using the USB cable. Note that the green debugger LED
(LED101) glows (pulsations may be observed, which is normal). If LED101 does not glow, it indicates that the
adapter or USB cable is faulty.
5. Connect the 6EDL_SPI_LINK to the target board and power on this board.
Figure 14
Verify USB connection and 6EDL_SPI_LINK basic functionality
Note:
6EDL_SPI_LINK may be warm to touch around the USB connector. This is normal and does not
indicate any fault.
6. On MOTIX™ BPA Motor Control Workbench, click New Project to create a new project using the 6EDL71x1
configurator (see
Figure
Note:
Older versions of the application support only the 6EDL7141; however, additional devices are
supported in later versions.
User guide
Launcher.
15).
10
V 1.0
2023-11-02