PVG 100 Component Troubleshooting
Failure mode
No pump pressure developed in one or more
valve sections

Shuttle Valve

26
PVG 100 Proportional Valves
Location: PVP/PVB Modules.
Function: Directs the highest load pressure to either OC or CC pump control to satisfy the operating
valve section.
Cause
LS passages blocked or restricted
Serviceability: Not serviceable. Ensure entire system is clean.
LS circuit
Description: Self cleaning internal shuttle system.
Location: PVB (valve section) module.
Function: Determines which valve section is developing highest load pressure.
11048807 • Rev BA • October 2014
Corrective action
Disassemble valve. Inspect passages for blockage