Position the cover plate so that the four threaded bolts pass completely through the holes of the fan cover plate. Screw in the
cover plate with four M8 hex nuts.
Figure 6
Screwing down the fan cover plate
6.
Tighten the bolts and nuts according to these instructions:
M12x30 hexagon screw: Wrench width 19 mm, the tightening torque is 46 Nm.
When tightening, make sure that the bezel brackets do not twist.
M6 hexagon nut: Wrench width 10 mm, the tightening torque is 8 Nm
M8 hexagon nut: Wrench width 13 mm, the tightening torque is 13 Nm
If you operate the charging station in accordance with German calibration law, then seal the cover plate with sealing
stickers
.
Figure 7
Sealing sticker
Installation of the cable management system
A5E53160522-AA, 11/2023
on the cover plate
Installing the cable management