Loosen the handle screw (I) and take off the front clip bar (L), and then change the front
squeegee (C).
Re-install the front squeegee blade in the reverse order of taking it off.
After changing the squeegee blade, adjust the level of the front and rear squeegee blades in
the procedures as described above.
4. Connect the Vacuum hose (11) to the squeegee.
5. Install the squeegee
6. If necessary,
adjust the squeegee by turning the adjustment knob (20) (refer to the procedures
for adjusting the balance of the squeegee).

BRUSH/ PAD CLEANING

CAUTION
When cleaning the brush/pad-driver, wearing protective gloves is
Recommended as the brush / pad may contain sharp debris.
1.
Remove the brush/pad-driver.
2.
With the use of water and detergents, clean the brush/pad driver.
3.
Check the brush for wear & if necessary, replace the brush.
4.
Check the pad driver for wear & if necessary, replace the pad driver.
WATER TANK AND FLOAT FILTER MESH CLEANING
1.
Move the machine to a dedicated draining area.
2. Press the power switch (38) to the position "O" to turn off the machine.
3. Open recovery tank lid (A, Figure 11), and remove the float device (36) from inside the tank.
4. Use
clean water to rinse the recovery tank lid (A), the tank (B and C), and the float filter support
frame (E). Drain all the water from the water tank.
5. If
necessary, following the symbols "Open" and "Close" as shown in Figure 11, open the bottom
lid (F) of the float filter and clean the float (D), float filter support frame (E), and the filter sponge
(I). After cleaning, re-attach the float onto the support frame (E), and then align the mark groove
(L) of the bottom lid (F) of the float filter with the mark groove (L) of the float filter support frame
(E). Turn the bottom lid (F) of the float filter tight, and re-attach the filter sponge (I) onto the
support frame (E), and then onto the vacuum tube (M).
6.
Inspect the seal / gasket (G) of the recovery tank lid.
NOTE
The seal / gasket (G) of the recovery tank allows the tank to create a vacuum. It
must be completely sealed to be able to effectively suck the wastewater from the
floor.
If necessary, If necessary, the recovery tank seal / gasket (G) may be taken out from the groove
(H) and changed. When installing the new seal / gasket as shown in Figure 11 below, install the