Download Print this page

Brush/Polishing Pad Cleaning; Water Tank And Float Filter Mesh Cleaning - Viper AS510B User Manual

Hide thumbs Also See for AS510B:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
4. Connect the Vacuum tube (11) to the squeegee.
5. Install the squeegee and use the knob (16) to tighten it, and then connect the Vacuum tube to the
squeegee.
6. If necessary, adjust the squeegee through the adjusting handwheel (20) (refer to the procedures
for adjusting the balance of the squeegee).

BRUSH/POLISHING PAD CLEANING

CAUTION!
When cleaning the brush/pad-holder, the wearing of protective gloves is
recommended because they may contain sharp fragments.
1. In the way as related in previous sections, take off the brush/pad-holder.
2. With the use of water and detergents, clean the brush/pad-holder.
3. Check the completeness and wearing condition of the bristles on the brush and, if necessary,
change the brush.
4. Check the wearing condition of the pad-holder and, if necessary, change the pad-holder.

WATER TANK AND FLOAT FILTER MESH CLEANING

1.
Move the machine to a dedicated dumping site.
2.
Press the power switch (41) to the position "O" to turn off the machine.
3.
Open recovery tank lid (A, Figure 16), and take off the float device (36) from recovery tank.
4.
Use pure water to clean recovery tank lid (A), the tank (B and C), and the float filter support frame
(E). Through the Recovery tube (15), drain all the water from the water tank.
5. If necessary, following the symbols "Open" and "Close" as shown in Figure 16, open the bottom
lid (F) of the float filter and clean the float (D), float filter support frame (E), and the filter sponge (I).
After cleaning, fix the float onto the float filter support frame (E), and then align the mark groove (L)
of the bottom lid (F) of the float filter with the mark groove (L) of the float filter support frame (E).
Turn the bottom lid (F) of the float filter tight, and fix the filter sponge (I) onto the float filter support
frame (E), and then onto the Vacuum tube (M).
6. Check the soundness of the sealing ring (G) of the water tank lid.
NOTE
The sealing strip (G) of the water tank makes the water tank create a vacuum. It
must be completely sealed to be able to effectively suck the wastewater from the
floor.
If necessary, the sealing strip of the water tank (G) may be taken out from the groove (H) and
changed. When assembling a new water tank sealing strip, as shown in Figure 16 below, install
the connector to the middle section of the rear part.
7. Check if the receiving surface of the sealing strip (G) is intact and seals adequately.
8. Close recovery tank lid (A).
USER MANUAL
Figure 15
15
ENGLISH

Hide quick links:

Advertisement

loading

This manual is also suitable for:

As430b