Standard Wiring Diagram - Emerson 2000LP Series Installation, Operation And Maintenance Manual

Low pressure pneumatic actuator
Table of Contents

Advertisement

Section 11: Limit Switch and Wiring Information
April 2013
11.2

Standard Wiring Diagram

Limit switches are supplied with a potted flexible connecting cable containing four wire leads;
one blue lead, one black lead, one brown lead and one gray lead. These leads are factory
prewired to the terminal strip (ETS) for each end of travel limit – see Figure 9.
NOTE:
When provided, solenoids will be wired to terminals 9, 10, 11 and 12, as shown in Figure 9.
Table 4.
400V
250V
30V
Figure 9
NOTE:
Limit switches are always wired to terminals #1 through #8 as shown, even when solenoids are
not provided.
20
Rated Switching Capacity
AC
Resistive Inductive Resistive Inductive
3A
2A
5A
3A
0.4A
7A
5A
Installation, Operation and Maintenance Manual
DC
0.03A
7A
5A
Part Number: E7K-400-0913
Limit Switch and Wiring Information