Emerson 2000LP Series Installation, Operation And Maintenance Manual page 15

Low pressure pneumatic actuator
Table of Contents

Advertisement

Section 7: Pneumatic Hookup
April 2013
Figure 3
7.
NOTE:
Do not use penetrating oils or detergent type oils as they will damage seals and thicken in cold
weather.
NOTE:
Any temperature below 32°F may require the addition of small amounts of pure ethylene glycol
into the air system to prevent freezing. Do not concede the volume of oil normally used.
NOTE:
This product, as well as similar devices such as cylinders, solenoid valves, ESD valves, etc. emit
air to atmosphere in their normal operating mode. Confer with established codes and safety
regulations.
CAUTION:
Use of the product on any power medium other than compressed air or nitrogen may establish
a potential hazard.
12
TYPICAL FILTER, REGULATOR AND LUBRICATOR PACKAGE
A lubricant is required for all internal moving parts of the air motor and air control
valves. This is intended to reduce wear and prevent rust. Brand name oils are suitable
if they are mineral base, wax free & aniline point in the range of 200-220°F. Oils must
be thin enough to atomize in the lubricator. This should be in the range of Group D,
Turbine Light with a viscosity of 32 at 100°F. Listed below is a representative group of
suitable light oils that may be considered for use.
Chevron - GTS OIl 32
Exxon - Teresstic T32
Mobil - Light
Shell - Turbo 32
Texaco - Capella 32 WF
Installation, Operation and Maintenance Manual
Part Number: E7K-400-0913
Pneumatic Hookup

Advertisement

Table of Contents
loading