E.C.I.
0034h
STATUS
SYSTEM
0035h
STATUS
0036h
Programming Level
【Input Group】
Name
Address
Pv.BSE
0037h
0038h
0039h
003Ah
RANGE
003Bh
ITO.MD
003Ch
TB.RST
003Dh
003Fh
0040h
0041h
0042h
0043h
0044h
0045h
【Relay Group】
Name
Address
0046h
0047h
Name
Address
0048h
0=Relay off 1=Relay on
0~1
External Control Input STATUS
bit0~bit2: E.C.I.1~ E.C.I.3;
0=Un-triged 1=Triged
SYSTEM STATUS
bit0=1, Input EEP fail;
bit1=1, Analogue Input calibration fail;
bit2=1, Analogue Input calibration NG;
bit3=1, Analogue Output calibration fail;
bit4=1, Analogue Output calibration NG
0~1
Reset Maximum & Minimum Value storage
0:No 1:Yes
Range
One Word Area
0~4
Time Base of PV(Immediately Value)
0: Second 1: Minute 2: Hour
3: K*Minute 4: K* Hour
0~1
Mode of Totalizer;
0:Normal 1:batch counter
0~1
Run mode after overflow
0:Overflow 1:Re-Cycle
0~1
Sign: Totalizer & Batch increase or
increase+decrease with +/- PV
0:Positive 1:Dual(Positive and negative)
0~2
Reading of Input Range Mode
0:Auto 1:Semi-Auto 2:Manual
Input Time Out Mode
0~1
0: Auto
0~1
The Reset for Totalizer and Batch
0:No 1:Yes
0~4
Display Mode of down screen
0: PV 1: Minimum Hold 2: Maximum Hold
3: RS485 4: Batch
-19999~19999
Low Cut(Immediately Value)
1~99
Average display for PV(Immediately Value)
0~99
Digital Filter for PV(Immediately Value)
1~9999
Pulse devider
0000~9999
Pass Code
0~3
Function Lock
0: none 1: User Level
3: All
Range
0000~9999
Start Band of input 1 for relay energized
0000~5999
Start Delay Time of input 1 for relay energized
(0.1second)
Range
0~11
Relay 1 Energized Mode
0: oFF(no use);
1: Lo(Low Energized);
2: Hi(High Energized)
Explain
1: Manual
2: Engineer Level
Explain
Explain
24 / 27
00h
00h
00h
Initial
Write/Read Note
00h
00h
00h
00h
00h
00h
00h
00h
0
5
0
1
1000
00h
Initial
Write/Read Note
0
0
Initial
Write/Read Note
9
CS2-TM(Pulse)-Operating Manual 2012-05-10
R
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W