Calibration parameters
Section
Parameters
Temperature
Humidity
Indoor
Absolute pressure
Relative pressure
Temperature
Humidity
Wind direction
Wind speed
Outdoor
Rain
UVI
Light
CH1~3
Temperature
Thermo-hygro
Humidity
(optional)
PM2.5 value
PM10 value
Others
sensors
HCHO value
(optional)
CO2 value
CO value
Note:
- Calibration of most parameter is not required, with the exception of Relative Pressure, which must
be calibrated to sea-level to account for altitude effects.
- For temperature and pressure, the app will always calculate & convert the calibration value in
and hPa respectively.

6.7 Firmware

Settings
Settings
Wi-Fi
Wi-Fi
Edit device
Edit device
W W eather server
eather server
Calibration
Calibration
Firmware
Firmware
Confirm & Exi
Confirm & Exit t
(a) Settings page
At the settings page, tap "Firmware".
Type of
Default
Calibration
value
Offset
0
±20°C
Offset
0
±20 %
Offset
0
±560hPa
(±16.54inHg or
Offset
0
±420mmHg)
Offset
0
±20°C
Offset
0
±20 %
Offset
0
±90°
Gain
1
x 0.5 ~1.5
Gain
1
x 0.5 ~1.5
Gain
1
x 0.01 ~ 10.0
Gain
1
x 0.01 ~ 10.0
Offset
0
±20°C
Offset
0
±20 %
Offset
0
±99μg/m³
Offset
0
±99μg/m³
Offset
0
±500ppb
Offset
0
±500ppm
Offset
0
±200ppm
Firmware version
(b) Your current firmware version will be
shown. Tap "Update" if new firmware is
available (indicated by a red dot).
47
Setting range
Typical calibration source
Red spirit or mercury thermometer
Sling psychrometer
Calibrated laboratory grade barometer
Local airport
Red spirit or mercury thermometer
Sling psychrometer
GPS or Compass
Calibrated laboratory grade wind meter
Sight glass rain gauge with meter
Calibrated laboratory grade UV meter
Calibrated laboratory grade solar
radiation sensor
Red spirit or mercury thermometer
Sling psychrometer
Calibrated laboratory grade PM2.5 sensor
Calibrated laboratory grade PM10 sensor
Calibrated laboratory grade HCHO
sensor
Calibrated laboratory grade CO2 sensor
Calibrated laboratory grade CO sensor
Firmware
1.00
New Firmware 1.01 available
Update
°
C
After firmware uploaded
to console, please check
status on your device,
please refer to (Section
8.3) for more detail.
GB

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

78035107009971

Table of Contents