Figure 6.1
MECHANICAL STOP
(DO NOT LOOSEN)
6.2.7
Emergency Stop
The Emergency Stop is a user control that will prevent the Actuator from running, and will
also immediately terminate a weld cycle and cause the Horn to retract. It does not remove
power from the system. The controls can be configured to provide a beep sound when the
emergency stop is engaged. The front panel display of the power supply will indicate that
the system is in emergency stop mode when it is.
100-412-182 REV. 06
Mechanical Stop Installation and Adjustment
SET SCREW
LOCKING NUT
INCREASE
STROKE
LENGTH
SET SCREW
MECHANICAL STOP
ADJUSTING KNOB
DECREASE
STROKE
LENGTH
73